SupremeRAID™ uses a GPU-based PCIe RAID card to protect NVMe storage. The Linux driver presents virtual NVMe drives to the operating system and manages RAID operations on the GPU.
This guide is for administrators who install and manage SupremeRAID™ Linux driver 2.0.1. It covers installation, storage configuration, command-line management, maintenance, and troubleshooting.
Run administrative commands with sudo or equivalent root privileges. Omit the displayed $ or # prompt when you enter a command.
Replace bracketed placeholders, such as [filename] and [LICENSE_KEY], with values for your system. Keep literal option names unchanged.
Check device paths and resource IDs on your host before you change storage. Example IDs and paths are not instructions to use those devices.
Shell blocks contain commands to run. Terminal windows show example sessions and results. Some sessions come from earlier driver versions; filenames, versions, IDs, and output can differ on 2.0.1.
Follow one installation or upgrade path. Do not run the alternative procedures in sequence.
A physical drive (PD) is an SSD assigned to SupremeRAID™ management. When you create a PD, the driver unbinds the SSD from the Linux NVMe driver. The original /dev/nvmeX device is no longer available. SupremeRAID™ creates a /dev/gpdX device for management tasks, such as reading the SSD model and SMART data.
To return the SSD to Linux NVMe access through /dev/nvmeXn1, first delete the corresponding PD. See Deleting a Physical Drive for the command and its restrictions.
SupremeRAID™ supports 32 physical drives, regardless of whether the physical drives are created from a native NVMe SSD, a drive connected through NVMe-oF, or a SAS/SATA disk.
The main component of RAID logic is a RAID group. When the drive group is created, the SupremeRAID™ driver initializes the physical drives with the corresponding RAID mode to ensure that the data and parity are synchronized.
There are two types of initialization processes.
Fast Initialization: When all the physical drives in the drive group (DG) support the de-allocate dataset management command, the SupremeRAID™ driver performs fast initialization by default, which optimizes the drive group state immediately.
Background Initialization: Performance is slightly affected by the initialization traffic, but you can still create the virtual drive and access the virtual drive during a background initialization. SupremeRAID™ supports eight drive groups, with a maximum of 32 physical drives in one drive group.
A virtual drive (VD) is a RAID volume that applications can use. You can create multiple VDs in one drive group. Each VD appears as /dev/gdgXnY in Linux. Create a file system on this device, or use it directly with an application that supports block devices. Each drive group supports up to 1,023 VDs.
The controller is the core component of the RAID system. It provides detailed hardware information such as GPU serial number, temperature, and fan speed. RAID management relies on the controller, so the controller's state directly affects the underlying drive group operations.
In the Linux driver, users can have dual controllers in the system and manage them separately. By enabling the high-availability function in a drive group, the backup controller will take over drive group management if the primary controller fails or goes missing. Additionally, you can set up drive groups on a specified controller or within the same NUMA node as the controller to minimize negative influences.
Note
If you upgrade from version 1.2.x to version 1.6.x of the SupremeRAID™ driver, the device path changes from /dev/gvdXn1 to /dev/gdgXnY.
A consistency check compares redundant data to detect inconsistencies. You can start a check manually or set a schedule. Select a policy to fix detected inconsistencies automatically or stop the check when it finds an error.
The consistency check function is not supported on SupremeRAID™ systems configured in RAID0 mode because RAID0 does not provide data redundancy and does not require data consistency checks.
In a dual-controller configuration, a second SupremeRAID™ card can take over drive groups when the active card fails or goes missing. SupremeRAID™ supports dual-active and active-passive configurations. The cards can use the same PCIe root complex or different root complexes. See the setup procedure for controller assignment and failover behavior.
SupremeRAID™ can use remote NVMe-over-Fabrics (NVMe-oF) devices as physical drives. Connect to a target over TCP or RDMA, then create and manage RAID resources from the connected devices.
SupremeRAID™ can export virtual drives to remote NVMe-oF initiators. The target service provides network access to local RAID volumes. A SmartNIC can accelerate network data transfer.
The Storage Performance Development Kit (SPDK) interface exposes SupremeRAID™ storage as SPDK block devices (bdevs). Applications can access NVMe queues from user space. This path bypasses the kernel block layer and reduces context switches. See Managing NVMe-oF Export Target (SPDK) for setup requirements.
SupremeRAID™ incorporates a distributed journaling mechanism specifically designed to safeguard data during abnormal shutdowns in double-failure scenarios. This system ensures data integrity by logging data in a dedicated journaling space before writing it to the storage area, any incomplete I/O operations are replayed upon service restart to maintain data consistency.
This journaling feature is automatically enabled in degraded mode to uphold data integrity. Additionally, users still have the flexibility to bypass journaling space reservation when creating a drive group.
The web management console provides Dashboard, Hosts, RAID Management, Events, and Statistics pages. Administrators can also manage licenses, user accounts, and email notifications. Configure SMTP settings and user notification preferences to receive event alerts.
With the release of Linux driver 1.6.1, the SupremeRAID™ driver introduces support for the NVMe DSM deallocate (trim) command on virtual drives, improving the efficiency of unused storage space management on NVMe SSDs. This feature allows filesystems or applications to issue deallocate commands on virtual drives, which are then translated by the driver and sent directly to the SSDs. By enabling the drives to manage deallocated blocks internally, this reduces write amplification, optimizes storage efficiency, and enhances overall performance.
When a discard command is issued to a virtual drive, it triggers a corresponding deallocate command to the underlying NVMe SSDs. The system supports a minimum discard range of 4KB, aligned with the logical block addressing (LBA) size, and can handle a maximum deallocate range of approximately 400 GiB per command. For larger discard operations, the filesystem and block layer handle the process seamlessly.
This feature is automatically enabled on NVMe SSDs that support the deallocate command and guarantee that deallocated blocks return zeros. For SSDs without this guarantee, the system defaults to a "write zeros" command to ensure data consistency. This flexible approach ensures broad compatibility across different SSDs while optimizing their individual capabilities.
To ensure the filesystem can take advantage of this capability and issue discard commands when files are deleted, it must be mounted with the discard option.
The driver retries failed physical-drive operations to handle transient read and write errors. This mechanism reduces the risk of marking a drive as failed because of a temporary error. Error retry support was introduced in Linux driver 1.7.0.
For this guide, use the packages and supported platform list in the 2.0.1 release notes. Upgrade procedures can require an intermediate release; use the version named in that procedure.
Reserve a maintenance window for hardware installation and host restarts.
Obtain administrator access and a license for the target release.
Record the host operating system, kernel version, and SupremeRAID™ model.
Back up existing data before you change storage configuration.
Confirm repository access before you use package-manager commands. Manual installation also requires access to its listed packages. For an offline deployment, obtain a validated dependency plan from Graid Technical Support before you start.
Before proceeding with the installation, make sure the system meets the following requirements:
The SupremeRAID™ card must be installed into a PCIe x16 slot.
Download the pre-installer and installer from the target release page. The pre-installer prepares dependencies and system settings. The installer installs the SupremeRAID™ driver for the detected distribution.
Make sure a SupremeRAID™-compatible SSD drive is being used. For a list of compatible drives, see the Drivers & Documentation section on our website.
System suspension and hibernation are currently unsupported due to a limitation in the NVIDIA driver.
[OPTIONAL] It is recommended to disable the IOMMU function (AMD) or VT-d function (Intel) in the system BIOS, typically on the BIOS Advanced page.
[OPTIONAL] Disable UEFI Secure Boot on the BIOS security page where your system policy permits it. If Secure Boot must remain enabled, sign the NVIDIA kernel module. Follow the NVIDIA instructions for your distribution.
Perform the following procedure to install SupremeRAID™ into your system.
Step 1 Power down your system.
Step 2 Unplug the power cord from the AC power source.
Step 3 Remove the side panel from your system to gain access to the motherboard.
Step 4 If your system has a PCIe card, remove it. If a retention bar is holding the card in place, remove the screw securing the card. If there is no existing PCIe card, remove the access covers from the primary x16 PCI express slot.
Remove PCIe Slot Cover
Note
The SupremeRAID™ SR-1010 is dual-slot card and requires you to remove two adjacent slot covers. The SupremeRAID™ SR-1000, SR-CORE-AM, SR-PRO-AM, SR-ULTRA-AD and SR-1001 are single-slot cards and require only a single-slot.
Step 5 Install the card into the primary x16 PCI Express slot. Press gently on the card until it is seated securely in the slot and reattach the SupremeRAID™ card bracket retention mechanism.
Install SupremeRAID Card PCIe Slot
Note
Install the SupremeRAID™ card into the primary x16 PCI Express slot. The SupremeRAID™ SR-1010 is dual-slot card and covers the adjacent slot. The SupremeRAID™ SR-1000, SR-CORE-AM, SR-PRO-AM, SR-ULTRA-AD and SR-1001 are single-slot cards. For more information, see NVIDIA RTX Ampere Architecture-Based Graphics Card User Guide.
Step 6 Secure the card to the system frame using the screw(s) you removed in step 4.
Step 7 Install the side panel you removed in step 3.
Use the pre-installer to prepare dependencies and system settings. Then run the installer to install the SupremeRAID™ driver. For an offline host, prepare the dependencies with the manual installation procedure. For an existing installation, follow Upgrading the Software.
The pre-installer prepares system dependencies, configures kernel settings, and installs the NVIDIA driver. The installer installs the SupremeRAID™ driver. Download both from the release page for your target driver version.
Note
To run the pre-installer, the system must have internet access to download the required dependencies from the official mirror.
Step 1 Download the pre-installer from Dependencies and Utilities in the 2.0.1 release notes. Make the file executable.
$ sudowget[filelink]$ sudochmod +x [Filename]
Step 2 Run the pre-installer. Follow the prompts to prepare the host.
$ sudo ./[filename]--productline=sr
root@graid-demo:/home/graid/driver# ./graid-sr-pre-installer-1.5.0-98-x86_64.run
Reading package lists... Done
Building dependency tree
Reading state information... Done
gawk is already the newest version (1:5.0.1+dfsg-1ubuntu0.1).
mokutil is already the newest version (0.6.0-2~20.04.2).
pciutils is already the newest version (1:3.6.4-1ubuntu0.20.04.1).
tar is already the newest version (1.30+dfsg-7ubuntu0.20.04.3).
0 upgraded, 0 newly installed, 0 to remove and 0 not upgraded.
Extracting installer files, please wait a few seconds ...
DKMS: install completed.
Setting kernel options
Sourcing file `/etc/default/grub'
Sourcing file `/etc/default/grub.d/init-select.cfg'
Generating grub configuration file ...
Found linux image: /boot/vmlinuz-5.4.0-163-generic
Found initrd image: /boot/initrd.img-5.4.0-163-generic
Adding boot menu entry for UEFI Firmware Settings
done
Setting kernel options done.
Generating new initramfs...
update-initramfs: Generating /boot/initrd.img-5.4.0-163-generic
Generated new initramfs.
Install packages and kernel setting succeeded.
Prepare install NVIDIA driver
Checking Xorg ...
Checking nouveau ...
Nouveau module has been loaded, graid-preinstaller will unload nouveau for NVIDIA driver install.
Unload nouveau module successfully.
Running install NVIDIA Driver. (This step will take a while.)
Wed Feb 21 11:27:41 2024
+---------------------------------------------------------------------------------------------+
| NVIDIA-SMI 535.154.05 Driver Version: 535.154.05 CUDA Version: 12.2 |
+---------------------------------------------------------------------------------------------+
| GPU Name Persistence-M | Bus-Id Disp.A | Volatile Uncorr. ECC |
| Fan Temp Perf Pwr:Usage/Cap | Memory-Usage | GPU-Util Compute M. |
| | | MIG M. |
+=============================================================================================+
| 0 NVIDIA RTX A2000 Off | 00000000:01:00.0 Off | 0 |
| 30% 32C P2 22W / 70W | 0MiB / 5754MiB | 0% Default |
| | | N/A |
+---------------------------------------------------------------------------------------------+
+---------------------------------------------------------------------------------------------+
| Processes: |
| GPU GI CI PID Type Process name GPU Memory |
| ID ID Usage |
+=============================================================================================+
| No running processes found |
+---------------------------------------------------------------------------------------------+
Install NVIDIA Driver succeeded.
This graid-preinstaller will reboot the system for apply previous setting!
Do you want to continue? [Y/n]
Pre Installer Execution Screen
Step 3 After running the pre-installation script, type Y and press Enter when prompted to reboot the system.
Step 4 Open Driver Package in the 2.0.1 release notes. Select your SupremeRAID™ model and confirm the associated GPU. Select Download, review the agreement, and download the installer. Make the file executable.
$ sudowget[filelink]$ sudochmod +x [filename]
Step 5 Execute the installer and follow the provided steps to complete the installation.
$ sudo ./[filename]
A. At the Welcome page, select Next and press Enter to view the end-user license agreement.
Installer Welcome Screen
B. In the end-user license agreement page, use the spacebar to scroll down the content. After you review the license, select Next and press Enter.
Installer License Agreement Screen
C. Type Accept, press Tab, select Next, and press Enter to accept the license agreement.
Installer License Acceptance Screen
D. Confirm the installation package, and then select Next to continue with the installation.
Installer Package Confirmation Screen
E. Complete the installation. You can access the SupremeRAID™ Management Console at https://[host-ip]:50060. If port 50060 is occupied by another application, see the instructions for changing the port.
Installer Complete Management Console Screen
If another application uses port 50060, edit /etc/graidmgr/service.conf. The following example uses port 8888 and address 172.16.12.34:
[common]web_port=8888web_addr="172.16.12.34"
If you no longer have the host token, generate one with the following command.
$ sudo graid-mgr host_token gen
Step 6 To activate the software, apply the SupremeRAID™ license key.
Use silent installation for scripts or unattended deployment. Run the pre-installer and installer as separate stages. Do not assume that --yes suppresses restarts. Validate restart behavior with the selected package before you use it in an unattended workflow. Review the end-user license agreement before you use --accept-license. This option accepts the agreement; it does not replace product activation with a license key.
Step 1 Download the pre-installer and installer as described in the previous section. Make both files executable.
$ sudochmod +x [filename]
Step 2 Run the pre-installer with --yes to prepare the host without interactive prompts.
$ sudo ./[filename]--yes
Step 3 Wait for the pre-installer to finish. If it requests or performs a restart, reconnect after the host starts before you run the installer. Run the installer with --accept-license to accept the end-user license agreement and install the driver.
$ sudo ./[filename] --accept-license
root@graid-demo:~/driver# sudo ./graid-sr-installer-1.5.0-001-659-82-x86_64.run --accept-license
Extracting installer files, please wait a few seconds ...
Extracting installer files done.
Starting installer ...
systemctl stop graid
Creating symlink /var/lib/dkms/grebar/0.1.0/source -> /usr/src/grebar-0.1.0
Kernel preparation unnecessary for this kernel. Skipping...
Building module:
cleaning build area...
make -j32 KERNELRELEASE=5.15.0-83-generic...
Signing module:
- /var/lib/dkms/grebar/0.1.0/5.15.0-83-generic/x86_64/module/grebar.ko
Secure Boot not enabled on this system.
cleaning build area...
grebar.ko:
Running module version sanity check.
- Original module
- No original module exists within this kernel
- Installation
- Installing to /lib/modules/5.15.0-83-generic/updates/dkms/
depmod...
Selecting previously unselected package graid-sr.
(Reading database ... 83819 files and directories currently installed.)
Preparing to unpack .../graid-sr-1.5.0-659.g10e76f72.001.x86_64.deb ...
No need to patch
Unpacking graid-sr (1.5.0) ...
Setting up graid-sr (1.5.0) ...
Creating symlink /var/lib/dkms/graid/1.5.0/source -> /usr/src/graid-1.5.0
Kernel preparation unnecessary for this kernel. Skipping...
Building module:
cleaning build area...
./build.sh 5.15.0-83-generic /lib/modules/5.15.0-83-generic/build.......
Signing module:
- /var/lib/dkms/graid/1.5.0/5.15.0-83-generic/x86_64/module/graid-nvidia.ko
- /var/lib/dkms/graid/1.5.0/5.15.0-83-generic/x86_64/module/graid.ko
Secure Boot not enabled on this system.
cleaning build area...
graid.ko:
Running module version sanity check.
- Original module
- No original module exists within this kernel
- Installation
- Installing to /lib/modules/5.15.0-83-generic/updates/dkms/
graid-nvidia.ko:
Running module version sanity check.
- No original module exists within this kernel
- Installation
- Installing to /lib/modules/5.15.0-83-generic/updates/dkms/
depmod...
Processing triggers for man-db (2.10.2-1) ...
Suggestion!! This installer will reboot the system for apply previous kernel module grebar setting!
Do you want to continue? [Y/n]
Silent Installer Accept License Screen
Step 4 Generate a host token and use it to log in to the SupremeRAID™ Management Console.
$ sudo graid-mgr host_token gen
Step 5 To activate the software, apply the SupremeRAID™ license key.
Use manual installation when you must prepare dependencies and kernel settings yourself. Complete only the procedure for your distribution, then run the installer. Check the supported distribution and kernel versions in the 2.0.1 release notes first.
For systems without internet access, download required dependencies from official repositories. See the distribution section below for details. Only perform manual installation if necessary or if the pre-installer fails. For most cases, check Supported Operating Systems on our website and use the automated pre-installer script to install the SupremeRAID™ software.
Use the following package table with the distribution-specific commands below. Kernel development packages must match the kernel used for installation. Please Use command to install packages directly: apt/yum -y install <pkg>
Proxmox VE Common: build-essentialpkg-configwgetmakeautomakelibelf-devgccg++dkmsipmitooltarinitramfs-toolsmdadmgdisklibsgutils2*libpci3sqlite3dialogperlnvme-clilibibverbs1libnuma1proxmox-headers-$(uname -r)libdw1t64
Step 2 Open the GRUB configuration file to edit the kernel command line. The following steps set kernel parameters and disable the Nouveau driver. These changes do not edit the system BIOS.
$ sudovim /etc/default/grub
Step 3 Append the command line parameters and then update the grub configuration based on your operating system.
For RHEL8, 9 and above versions, append iommu=pt and nvme_core.multipath=Y to GRUB_CMDLINE_LINUX_DEFAULT.
For RHEL7.9, append iommu=pt to ‘GRUB_CMDLINE_LINUX_DEFAULT’.
$ sudo grub2-mkconfig -o /boot/grub2/grub.cfg
Step 4 Append blacklist nouveau and options nouveau modeset=0 to the end of the file /etc/modprobe.d/graid-blacklist.conf to disable the Nouveau driver and update initramfs.
$ sudo update-initramfs -u
root@graid-demo:/etc/modprobe.d# cat graid-blacklist.conf
blacklist nouveau
options nouveau modeset=0
Nouveau Blacklist Config Example
Step 5 Regenerate initramfs for your distribution.
For CentOS, Rocky Linux, and AlmaLinux: Find the latest version of the kernel and assign it to –kver.
Step 4 Open the GRUB configuration file to edit the kernel command line. The following steps set kernel parameters and disable the Nouveau driver. These changes do not edit the system BIOS.
$ sudovim /etc/default/grub
Step 5 Append iommu=pt and nvme_core.multipath=Y to GRUB_CMDLINE_LINUX_DEFAULT, and then update the grub configuration.
$ sudoupdate-grub
Step 6 Append blacklist nouveau and options nouveau modeset=0 to the end of the /etc/modprobe.d/graid-blacklist.conf file to disable the Nouveau driver and update initramfs.
$ sudo update-initramfs -u
root@graid-demo:/etc/modprobe.d# cat graid-blacklist.conf
blacklist nouveau
options nouveau modeset=0
Ubuntu Nouveau Blacklist Config Example
Note
You might need to manually create the /etc/modprobe.d/graid-blacklist.conf file and append blacklist nouveau and options nouveau modeset=0.
Step 7 Reboot the system and make sure the grub configuration was applied. You can check /proc/cmdline for the grub configuration in use. For example:
root@graid-demo:/etc/modprobe.d# cat /proc/cmdline
BOOT_IMAGE=/boot/vmlinuz-5.15.0-46-generic root=UUID=32b02b62-7173-4f3b-a723-8aa1e2fbf60a ro text iommu=pt nvme_core.multipath=Y
Ubuntu GRUB cmdline Example
Step 8 Install the NVIDIA driver (The following is a sample. For the latest NVIDIA driver version, see the Release Notes).
Note
For GPUs with NVLink/NVSwitch, see the Knowledge Base for guidance on installing the NVIDIA Fabric Manager.
Step 3 Open the GRUB configuration file to edit the kernel command line. The following steps set kernel parameters and disable the Nouveau driver. These changes do not edit the system BIOS.
$ sudovim /etc/default/grub
Step 4 Append iommu=pt and nvme_core.multipath=Y to GRUB_CMDLINE_LINUX_DEFAULT, and then update the grub configuration.
$ sudo grub2-mkconfig -o /boot/grub2/grub.cfg
Step 5 Append ‘blacklist nouveau’ to the end of the /etc/modprobe.d/graid-blacklist.conf file to disable the Nouveau driver. You might need to manually create the /etc/modprobe.d/graid-blacklist.conf file and append blacklist nouveau and options nouveau modeset=0.
root@graid-demo:/etc/modprobe.d# cat graid-blacklist.conf
blacklist nouveau
options nouveau modeset=0
openSUSE Nouveau Blacklist Config Example
Step 6 Set the allow_unsupported_modules option to 1 in the /etc/modprobe.d/10-unsupported-modules.conf file and update initrd.
$ sudo mkinitrd
Step 7 Reboot the system and make sure the grub configuration was applied. You can check /proc/cmdline for the grub configuration in use. For example:
Step 3 Open the GRUB configuration file to edit the kernel command line. The following steps set kernel parameters and disable the Nouveau driver. These changes do not edit the system BIOS.
$ sudovim /etc/default/grub
Step 4 Append iommu=pt and nvme_core.multipath=Y to GRUB_CMDLINE_LINUX_DEFAULT, and then update the grub configuration:
$ sudo grub2-mkconfig -o /boot/grub2/grub.cfg
Step 5 Append blacklist nouveau to the end of the /etc/modprobe.d/graid-blacklist.conf file to disable the Nouveau driver. You might need to manually modify the configuration file.
root@graid-demo:/etc/modprobe.d# cat graid-blacklist.confblacklist nouveauoptions nouveau modest=0
Step 6 Set the allow_unsupported_modules option to 1 in the /etc/modprobe.d/10-unsupported-modules.conf file and update initrd.
$ sudo mkinitrd
Step 7 Reboot the system and make sure the grub configuration was applied. You can check /proc/cmdline for the grub configuration in use. For example:
Step 1 Execute the installer and follow the provided steps to complete the installation.
$ sudo ./[Filename]
Step 2 At the Welcome page select Next and press Enter to view the end-user license agreement.
Manual Installer Welcome Screen
Step 3 In the end-user license agreement, use the spacebar to scroll through the content. When you complete your review, select Next and press Enter to proceed.
Manual Installer License Review Screen
Step 4 Type accept, press Tab, select Next, and press Enter to accept the license agreement.
Manual Installer License Acceptance Screen
Step 5 Complete the installation, and the installer will reboot the system.
Manual Installer Complete Screen
Step 6 To activate the software, apply the SupremeRAID™ license key. Driver 2.0 requires a V2 license key.
Use the web management console to manage RAID resources, view events, and monitor storage. Install the driver and apply a license before you enable the console service.
Step 5 Open a web browser, go to https://[host-ip]:50060, log in with the default account, and enter the host token in the SupremeRAID™ Management Console.
Management Console Host Token Login
If you no longer have the host token, generate one with the following command.
$ sudo graid-mgr host_token gen
Step 6 Set up a password. You can also use the following command to set up the admin password.
$ sudo graid-mgr set admin password
Management Console Set Admin Password
Note
The default account for graphical management console is ‘admin’.
Schedule a console interruption before changing the listening address. Confirm that the new address belongs to the host and that the chosen port is available. Update the corresponding firewall rule.
Edit /etc/graidmgr/service.conf to set the console port and IP address. The following example uses port 8888 and address 172.16.12.34:
[common]web_port=8888web_addr="172.16.12.34"
After saving a console configuration change, restart graid-mgr.service. Open the console at the new address and port and confirm that you can sign in.
This section describes how to use the basic functions of SupremeRAID™. It consists of step-by-step examples and command instructions that guide you to accessing all SupremeRAID™ features.
When you install the SupremeRAID™ driver, you must activate the SupremeRAID™ service by applying a license key obtained from your vendor before using the service. After activation, you can create drive groups, create virtual drives, and perform the other management operations described in this guide.
To check the SupremeRAID™ driver version, issue:
$ sudo graidctl version
To activate the SupremeRAID™ software, issue:
$ sudo graidctl apply license [LICENSE_KEY]
To check the license information, issue:
$ sudo graidctl describe license
To check the controller status, issue:
$ sudo graidctl list controller
Verification
Confirm that the license state is APPLIED and the expected controller is ONLINE. If either check fails, stop and use Troubleshooting.
Controller replacement and deletion are maintenance operations. See Managing Controllers.
To apply the license, you might need to provide the NVIDIA GPU serial number to Graid Technology Technical Support. Use one of the following commands to obtain the serial number for all NVIDIA cards in your environment:
If two controllers are activated in the graid.conf system configuration file, the SupremeRAID™ service prevents you from activating any additional controllers until one of the existing controllers is removed. This safeguard prevents conflicts and ensures proper system operation. Exercise caution and consult the software documentation or seek professional assistance if needed.
Use only drives that are available for a new array. Confirm each drive by its identity and contents before you create a PD. Do not select the operating-system drive or a drive that contains data you must retain.
This example creates five PDs, one RAID 5 DG, and a 5 TB VD. It uses /dev/nvme0 through /dev/nvme4 and assumes the new DG receives ID 0. Check the available drives and assigned IDs on your host first.
Confirm that the new VD appears with the expected capacity and an OPTIMAL state. Record its device path before you create a filesystem. See Configuring persistent mounts.
Use this example only when you intend to create a RAID 6 DG without reserved journal space. Check the journal behavior described below before you use --no-journal.
To replace the SSD that is nearly worn-out or broken:
Step 1 Check the status of the physical drive. If the drive is already displaying as MISSING or another abnormal status, you can skip step 2 and go directly to step 3.
$ sudo graidctl list pd
Step 2 If the physical drive status is “online”, mark the physical drive as BAD.
$ sudo graidctl edit pd [OLD_PD_ID] marker bad
Step 3 Replace the NVMe SSD. The state of the previous physical drive will indicate FAILED.
To activate the HA feature, you need two SupremeRAID™ cards installed in your server model and have the service activated. One drive group can only run on one controller. However, the number of drive groups assigned to each controller does not need to be equal.
If one controller fails and the auto-failover function is turned on (it is enabled by default), the drive group under the failed controller fails over immediately to the functioning controller. To ensure data integrity, the drive group statuses that failover switch to Resync mode.
Step 1 Activate two cards to enable the HA feature.
Typically, there is no need to set the controller manually while creating a drive group because SupremeRAID™ selects the optimal controller automatically based on the chosen physical drive. However, it is possible to adjust the controller manually for the drive group by making edits to it.
Record the current driver version, license state, and PD, DG, and VD inventory. Back up the data and configuration. Resolve missing or degraded resources before upgrading. Schedule host restarts and stop applications that use the affected volumes.
The migration examples in this chapter target the 2.0 release series. For a later maintenance release, confirm the supported path in that release’s notes before selecting packages.
Select an upgrade path based on the installed driver version. Follow either the silent or manual procedure for that path. Do not combine steps from different paths.
Installed version
Required path to 2.0
Earlier than 1.7.2 Update 67
Upgrade to 1.7.2 Update 67 first. Wait for the DGs and VDs to return to OPTIMAL, then continue to 2.0.
1.7.2 Update 67 or later in the 1.7 series
Follow the direct upgrade procedure to 2.0.
Driver 2.0 requires a V2 license key. Obtain the key before the upgrade. The procedures below retain the 1.7 intermediate path and the 2.0 migration sequence. Check the target release notes for package and platform requirements.
If an upgrade fails, stop the procedure. Collect the logs and contact Graid Technical Support.
For this 1.7 upgrade path, run the pre-installer and installer without uninstalling the existing SupremeRAID™ driver. The --accept-license option accepts the end-user license agreement. Apply a product license separately if required.
Step 1 Stop all applications running on the virtual drive.
Step 2 Stop the management service. If the management console is enabled, stop its service as well.
Step 5 Download the 2.0 driver package (Pre-installer & Installer) and make it executable.
Step 6 Run the 2.0 Pre-installer first, it will automatically check the required dependencies and install the NVIDIA driver.
$ sudo ./[filename]--yes
Step 7 Run the 2.0 installer with --accept-license to accept the end-user license agreement.
$ sudo ./[filename] --accept-license
Step 8 Check the driver version to ensure the upgrade is successful.
$ sudo graidctl version
Step 9 Use nvidia-smi to check the serial number of the SupremeRAID™ Card. (If the license has already been applied, this step can be skipped). Driver 2.0 requires a V2 license key.
First upgrade to 1.7.2 Update 67. Wait for all DGs and VDs to return to OPTIMAL before you continue to 2.0. Obtain a V2 license key from Graid sales before you start.
Step 1 Stop all applications running on the virtual drive.
Step 2 Stop the management service. If the management console is enabled, stop its service as well.
Step 8 After installing 1.7.2 Update 67, the VDs and DGs can temporarily enter TRANSFORMING. Wait until all VDs and DGs return to OPTIMAL before you continue.
Step 11 Download the 2.0 driver package (Pre-installer & Installer) and make it executable (repeat Step 4 to Step 7). Driver 2.0 requires a V2 license key.
Step 3 Make sure the SupremeRAID™ kernel module is unloaded.
$ sudo rmmod graid_nvidia graid
Step 4 Check the NVIDIA driver DKMS status.
$ sudo dkms status nvidia
Step 5 Check that the installed NVIDIA driver is a supported version for the target SupremeRAID™ release. If it is not supported, replace it as follows.
A. Dracut the initramfs (CentOS, Rocky Linux, AlmaLinux, and RHEL).
Step 4 Make sure the SupremeRAID™ kernel module is unloaded.
$ sudo rmmod graid_nvidia graid
Step 5 Check the NVIDIA driver DKMS status.
$ sudo dkms status nvidia
Step 6 Check that the installed NVIDIA driver is a supported version for the target SupremeRAID™ release. If it is not supported, replace it as follows.
A. Dracut the initramfs (CentOS, Rocky Linux, AlmaLinux, and RHEL).
First upgrade to 1.7.2 Update 67. Wait for all DGs and VDs to return to OPTIMAL before you continue to 2.0. Obtain a V2 license key from Graid sales before you start.
Step 1 Stop all applications running on the virtual drive.
Step 2 Stop the management service. If the management console is enabled, stop its service as well.
Step 3 Make sure the SupremeRAID™ kernel module is unloaded.
$ sudo rmmod graid_nvidia graid
Step 4 Check the NVIDIA driver DKMS status.
$ sudo dkms status nvidia
Step 5 Check that the installed NVIDIA driver is a supported version for the target SupremeRAID™ release. If it is not supported, replace it as follows.
A. Dracut the initramfs (CentOS, Rocky Linux, AlmaLinux, and RHEL).
Step 11 After installing 1.7.2 Update 67, the VDs and DGs can temporarily enter TRANSFORMING. Wait until all VDs and DGs return to OPTIMAL before you continue.
Step 14 Download the 2.0 driver package (Pre-installer & Installer) and make it executable (repeat Step 9 to Step 10). Driver 2.0 requires a V2 license key.
After an upgrade, confirm the intended driver version with graidctl version. Check the license, controllers, DGs, and VDs. Confirm that expected resources are present and healthy before you mount filesystems and resume applications. If a check fails, preserve the logs and stop the upgrade workflow.
Step 4 Make sure the SupremeRAID™ kernel module is unloaded.
$ sudo rmmod graid_nvidia graid
Step 5 Check the NVIDIA driver DKMS status.
$ sudo dkms status nvidia
Note
Check that the NVIDIA driver supports the replacement card and the target SupremeRAID™ release. Use the NVIDIA driver version listed in the target release notes.
Step 6 Uninstall the package using the command appropriate for your operating system:
For CentOS, Rocky Linux, AlmaLinux, RHEL, openSUSE, and SLES:
$ sudorpm-e graid-sr
For Ubuntu:
$ sudo dpkg -r graid-sr
Step 7 Confirm that the SupremeRAID™ module is unloaded, the output should be empty.
$ sudo lsmod |grep graid
Step 8 Confirm that the SupremeRAID™ package is uninstalled using the command appropriate for your operating system, the output should be empty.
CentOS, Rocky Linux, AlmaLinux, RHEL, openSUSE, and SLES:
$ sudorpm-qa|grep graid
Ubuntu:
$ sudo dpkg -l|grep graid
Step 9 Power-off the server, and then install the new card into the server.
Step 10 Power-on the server.
Step 11 Download the installer for the replacement card from the 2.0.1 release notes. Select the replacement model and confirm its GPU. Make the file executable.
If you are replacing a card in the system, deleting any inactive or invalid licenses associated with the old card is essential. Failing to do so may prevent other cards from becoming active, which is key for multi-controller systems.
Use this chapter as a command reference. For a first installation, complete the installation and activation procedures before you create storage. Command options describe available operations; they are not a sequence to execute.
Before a command that changes or deletes a resource, use its list or describe command to confirm the ID, state, and affected devices. After the change, repeat the check and confirm the expected result.
command: Specifies the operation to perform on one or more resources (for example create, list, describe, and delete).
OBJECT_TYPE: Specifies the object type. Object types are case-sensitive (for example license, physical_drive, and drive_group).
OBJECT_ID: Specifies the object ID. Some commands support simultaneous operations on multiple objects. You can specify the OBJECT_ID individually or use a dash to describe an OBJECT_ID range. For example, to delete physical drives 1, 3, 4, and 5 simultaneously, issue the command:
$ sudo graidctl delete physical_drive 13-5
flags: Optional command options. Use --help to view the options for a command:
$ sudo graidctl list virtual_drive --help
Use --format json to print JSON output:
$ sudo graidctl list virtual_drive --format json
For general help, run graidctl help. The quick reference below lists full command names and their aliases.
When applying the license, you must provide the serial number of the NVIDIA GPU to Graid Technology Technical Support. To obtain the NVIDIA GPU serial number, issue one of the following commands:
You can prompt the version command to check SupremeRAID™ service information. To obtain the SupremeRAID™ service version information, run the following command:
$ sudo graidctl version [flags]
Example output:
[root@graid ~]# graidctl version
✔Graidctl version successfully.
graidctl version: 1.6.0-rc1-243.g25b840a5.000
graid_server version: 1.6.0-rc1-243.g25b840a5.000
Current SID password of the SEDs. Can be used with either --sed-take-ownership or --sed-import-key
-i, --sed-import-key
Import the ‘’SED key” of the Self-Encrypting Drives (SEDs). It will ask for the current SID password, which must also be the admin’s password. The password will be saved as the SED key of the drive
-k, --new-sed-key string
Set a new SED key of the drives. Can only be used with --sed-take-ownership
-n, --no-current-sid
Indicates that Block SID authentication is currently disabled on the SEDs. Can only be used with --sed-take-ownership
-o, --sed-take-ownership
Take ownership of the SEDs with the specified new SED key. Can be used with one of --no-current-sid, --new-sed-key, and --psid to specify the authentication method
-p, --psid string
Physical Secure ID (PSID) of SEDs. Can only be used with --sed-take-ownership
-t, --type string
Specify product type of physical drive, SR, VROC or MD (default "SR")
Flag
Description
-p, --confirm-to-erase
Confirm to erase all data on the SED supporting physical drives forcibly
-w, --wipe-metadata
Wipe metadata forcibly
Example output:
$ sudo graidctl create physical_drive /dev/nvme0-1✔Create physical drive successfully.✔Create physical drive SR PD0 (/dev/nvme0: nqn.2019-10.com.kioxia:KCDXXXXXXXXX:55XXXXXXXXXX) successfully.✔Create physical drive SR PD1 (/dev/nvme1: nqn.2019-10.com.kioxia:KCDXXXXXXXXX:55XXXXXXXXXX) successfully.$ sudo graidctl create physical_drive nqn.2019-10.com.kioxia:KCDXXXXXXXXX:55XXXXXXXXXX nqn.2019-10.com.kioxia:KCDXXXXXXXXX:55XXXXXXXXXX✔Create physical drive successfully.✔Create physical drive SR PD4 (nqn.2019-10.com.kioxia:KCDXXXXXXXXX:55XXXXXXXXXX) successfully.✔Create physical drive SR PD5 (nqn.2019-10.com.kioxia:KCDXXXXXXXXX:55XXXXXXXXXX) successfully.$ sudo graidctl c pd /dev/nvme2,3✔Create physical drive successfully.✔Create physical drive SR PD2 (/dev/nvme4: nqn.2019-10.com.kioxia:KCDXXXXXXXXX:55XXXXXXXXXX) successfully.✔Create physical drive SR PD3 (/dev/nvme5: nqn.2019-10.com.kioxia:KCDXXXXXXXXX:55XXXXXXXXXX) successfully.
Slot ID of the corresponding NVMe/SAS/SATA drive. The PD ID is not related to the SLOT ID. To set the physical drives, use the PD ID.
DG ID
Drive group ID of the physical drive
PD ID
PD ID. The PD ID is a unique ID provided by the SupremeRAID™ driver when the physical drive is created. It is not related to any SSD information such as slot ID or NQN. The PD ID is used for all further operations.
NQN/WWID
NQN or WWID of corresponding NVMe/SAS/SATA drive
MODEL
Model number of the corresponding NVMe/SAS/SATA drive
CAPACITY
Capacity of corresponding NVMe/SAS/SATA drive
NODE
NUMA NODE of the corresponding NVMe/SAS/SATA drive
STATE
State of the physical drive (see the following table).
Physical drive state:
State
Description
ONLINE
Physical drive was added to a drive group and is ready to work.
HOTSPARE
Physical drive is configured as a hot spare drive.
FAILED
Physical drive is detected, but it is not operating normally.
OFFLINE
Physical drive is marked as offline.
REBUILD
Physical drive is being rebuilt.
MISSING
Physical drive cannot be detected.
UNCONFIGURED_GOOD
Physical drive did not join a drive group.
UNCONFIGURED_BAD
Physical drive did not join a drive group and is not operating normally.
COPYBACK
Physical drive is performing copyback.
If an (!) appears after the state mentioned above, it represents a critical warning.
To view detailed information for a physical drive, run the following command:
$ sudo graidctl describe physical_drive [PD_ID]
Alternatively:
$ sudo graidctl desc pd [PD_ID]
Command options:
Flag
Description
-t, --type string
Specify product type of Physical Drive, SR, VROC or MD
Example output:
$ sudo graidctl desc pd 0✔Describe physical drive successfully.PD ID: 0DG ID: 0Type: SRSlot ID: N/AGUID: nqn.2018-01.com.wdc:NGUID:0014EE840XXXXXXXXXXXXModel: WUS5EA176ESP5E1Serial: 22070XXXXXXCapacity: 7.0 TiBState: ONLINEDevice Path: /dev/gpd0Numa Node: 1Volatile Cache: N/ADeallocate: EnabledWearout: 4%Critical Warning: No warning.Assumed Clean: falseSED State: Not SupportedAttributes: locating =false hotspare =SMART Log: Critical Warning :0 Composite Temperature :39°C Available Spare :100% Available Spare Threshold :10% Percentage Used :4% Endurance Group Critical Warning Summary :0 Data Units Read :14432213326 Data Units Written :3236832168 Host Read Commands :143408102928 Host Write Commands :126310789360 Controller Busy Time :185198 Power Cycles :86 Power On Hours :20792 Unsafe Shutdown :54 Media and Data Integrity Errors :0 Number of Error Information Log Entries :3499 Warning Composite Temperature Time :0 Critical Composite Temperature Time :0 Thermal Management T1 Transition Count :0 Thermal Management T2 Transition Count :0 Thermal Management T1 Total Time :0 Thermal Management T2 Total Time :0 Updated Time :2026-04-17 03:59:53 +0000 UTC
$ sudo graidctl desc pd 0-t vroc✔Describe physical drive successfully.PD ID: 0DG ID: 0,2Type: VROCSlot ID: N/AGUID: nqn.2019-10.com.kioxia:KXXXXXXXXXXXModel: KCD61LUL3T84Serial: 21XXXXXXXXXXCapacity: 3.5 TiBState: ONLINEDevice Path: /dev/nvme0n1Numa Node: 1Wearout: 4%Critical Warning: No warning.SED State:Attributes: locating =false hotspare =SMART Log: Critical Warning :0 Composite Temperature :38°C Available Spare :100% Available Spare Threshold :44% Percentage Used :4% Endurance Group Critical Warning Summary :0 Data Units Read :20888852680 Data Units Written :2142466451 Host Read Commands :155595430042 Host Write Commands :66779158368 Controller Busy Time :95849 Power Cycles :153 Power On Hours :36506 Unsafe Shutdown :80 Media and Data Integrity Errors :0 Number of Error Information Log Entries :6367 Warning Composite Temperature Time :0 Critical Composite Temperature Time :0 Thermal Management T1 Transition Count :0 Thermal Management T2 Transition Count :0 Thermal Management T1 Total Time :0 Thermal Management T2 Total Time :0 Updated Time :2026-04-17 03:59:52 +0000 UTC
$ sudo graidctl desc pd 0-t md✔Describe physical drive successfully.graidctl desc pd 0-t md✔Describe physical drive successfully.PD ID: 0DG ID: 0Type: MDSlot ID: N/AGUID: nqn.2019-08.org.XXXXXXXXModel: QEMU NVMe CtrlSerial: NVXXXXXCapacity: 20 GiBState: ONLINEDevice Path: /dev/nvme1n1Numa Node: 0Wearout: 0%Critical Warning: No warning.SED State:Attributes: locating =false hotspare =SMART Log: Critical Warning :0 Composite Temperature :50° Available Spare :0% Available Spare Threshold :0% Percentage Used :0% Endurance Group Critical Warning Summary :0 Data Units Read :6929 Data Units Written :30599 Host Read Commands :508028 Host Write Commands :31464 Controller Busy Time :0 Power Cycles :0 Power On Hours :23 Unsafe Shutdown :0 Media and Data Integrity Errors :0 Number of Error Information Log Entries :0 Warning Composite Temperature Time :0 Critical Composite Temperature Time :0 Thermal Management T1 Transition Count :0 Thermal Management T2 Transition Count :0 Thermal Management T1 Total Time :0 Thermal Management T2 Total Time :0 Updated Time :2026-04-17 12:15:31 +0800 CST
Make sure the system or other applications are not on the physical drive before creating or replacing the drive.
To replace a nearly worn-out or broken SSD:
Step 1 If the physical drive is in the MISSING or other abnormal state, skip this step. Otherwise, run the following command to mark the physical drive as bad:
$ sudo graidctl edit pd [OLD_PD_ID] marker bad
Command options:
Flag
Description
-t, --type string
Specify product type of physical drive, SR, VROC or MD (default "SR")
Example output:
$ sudo graidctl edit pd 1-2 marker bad✖Edit physical drive failed: Failed to edit some PDs.✔Edit physical drive SR PD2 successfully.✖Edit physical drive SR PD1 failed: PD1(nqn.2019-10.com.kioxia:XXXXXXXXX) not in valid state: unconfigured bad
Step 2 Replace the NVMe SSD. The state of the prior physical drive indicates FAILED.
Specify product type of physical drive, SR, VROC or MD (default "SR")
Example output:
graid@graid-demo ~]$ sudo graidctl create drive_group raid1 0-1
✔Create drive group successfully.
✔Create drive group SR DG1 successfully.
Create Drive Group Output
Required parameters:
Option
Description
RAID_MODE
RAID mode of the drive group. Entries must be all uppercase or all lowercase. For example, RAID6 or raid6 are both correct.
PD_IDs
ID of the physical drive joining the drive group.
Optional parameters:
Option
Description
Behavior
--background-init, -b
Default option. Use standard methods to initialize the drive group. When all the physical drives in the drive group support the de-allocate dataset management command, it is used to synchronize the data, or parity, between the physical drives during drive group creation.
An I/O-capable device path similar to /dev/gdg0n1 is created.
--foreground-init, -z
Foreground initialization. This method writes zeros to the entire drive.
The virtual drive appears in the system after initialization is complete. Use sudo graidctl list drive_group to check the initialization progress.
--controller, -c
Specific controller to control this drive_group. Default: -1, [Int32]
The drive group is controlled by the specified controller.
--no-journal
Bypass the creation of journal space in the drive group.
The drive group will not create journal space.
--strip-size, -s
Strip size of the drive_group. [RAID0, RAID10] Values: 4, 8, 16, 32, 64, 128 Default: 4, [Int32]
Adjust RAID0/RAID10 strip size to a specific size: 4K, 8K, 16K, 32K, 64K, or 128K.
Wait for the drive group initialization to complete. DO NOT power-off or reboot the system when the drive_group state is INIT, RESYNC, or RECOVERY.
To check the drive group state, run the following command:
$ sudo graidctl list drive_group
Alternatively:
$ sudo graidctl ls dg
Example output:
$ sudo graidctl ls dg✔List drive group successfully.│──────────│───────│────────│────────│──────────│──────│─────────│──────────────────────│────────────────────────────────││ TYPE (4) │ DG ID │ MODE │ VD NUM │ CAPACITY │ FREE │ USED │ CONTROLLER │ STATE ││──────────│───────│────────│────────│──────────│──────│─────────│──────────────────────│────────────────────────────────││ SR │ 0 │ RAID1 │ 1 │ 1.5 TiB │ 0 B │ 1.5 TiB │ running: 0 prefer: 0 │ OPTIMAL ││──────────│───────│────────│────────│──────────│──────│─────────│──────────────────────│────────────────────────────────││ SR │ 0 │ RAID1 │ 1 │ 3.5 TiB │ 0 B │ 3.5 TiB │ running: 0 prefer: 0 │ INIT(dealloc)(1.45%) ││──────────│───────│────────│────────│──────────│──────│─────────│──────────────────────│────────────────────────────────││ VROC │ 1 │ RAID10 │ 1 │ 600 GiB │ 0 B │ 600 GiB │ running: 0 │ OPTIMAL ││──────────│───────│────────│────────│──────────│──────│─────────│──────────────────────│────────────────────────────────││ VROC │ 2 │ RAID1 │ 1 │ 0 B │ 0 B │ 0 B │ running: 0 │ OFFLINE ││──────────│───────│────────│────────│──────────│──────│─────────│──────────────────────│────────────────────────────────│
$ sudo graidctl ls dg -t md✔List drive group successfully.│──────│───────│───────│────────│──────────│──────│────────│────────────│──────────────────────────────────────────││ TYPE │ DG ID │ MODE │ VD NUM │ CAPACITY │ FREE │ USED │ CONTROLLER │ STATE ││──────│───────│───────│────────│──────────│──────│────────│────────────│──────────────────────────────────────────││ MD │ 0 │ RAID1 │ 1 │ 14 GiB │ 0 B │ 14 GiB │ running: 0 │ RECOVERY (in-progress) ││ │ │ │ │ │ │ │ │ PD 0: ONLINE ││ │ │ │ │ │ │ │ │ PD 1: OFFLINE ││ │ │ │ │ │ │ │ │ PD 2: REBUILD (6.25%, 1 mins remaining) ││──────│───────│───────│────────│──────────│──────│────────│────────────│──────────────────────────────────────────│The state represents the current status of the disk partition.
Output fields:
Flag
Description
DG ID
Drive group ID
MODE
Drive group RAID mode
VD NUM
Number of virtual drives in the drive group
CAPACITY
Total usable capacity of the drive group
FREE
Unused space of the drive group
USED
Used space of the drive group
CONTROLLER
Drive group controlled by the specific controller
STATE
Drive group state (see the following table)
Drive group state:
State
Description
OFFLINE
Drive group is not working properly. This condition usually occurs when the number of damaged physical drives exceeds the limit.
OPTIMAL
Drive group is in optimal state.
OPTIMAL (!)
Drive group is in optimal state but found inconsistency data.
OPTIMAL (cc)
Drive group is in optimal state and the consistency check task is ongoing.
OPTIMAL (cp)
Drive group is in optimal state and the copyback task is ongoing.
OPTIMAL (cc!)
Drive group is in optimal state and the consistency check task is ongoing but found inconsistent data.
DEGRADED
Drive group is available and ready for use, but the number of missing or failed physical drives has reached the limit.
PARTIALLY_DEGRADED
Drive group is available and ready for use, but some physical drives are missing or failed.
RECOVERY
Drive group is recovering
FAILED
Drive group is not working normally.
INIT(pending)
Initialization has not started yet.
INIT(dealloc)
Drive group is performing deallocating (discarding) and user I/O is prohibited.
INIT(zero)
Drive group is performing foreground initialization by writing zeros and user I/O is prohibited.
INIT(background)
Drive group is performing background initialization (resync) and user I/O is allowed.
RESYNC
Drive group is resynchronizing and remains available and ready for use. This condition usually occurs when the system encounters an abnormal crash. Do not replace the physical drive in this state until the resynchronization process completes.
RESCUE
Drive group is in rescue mode and can only be read.
Physical drive state in the MD drive group:
State
Description
ONLINE
The member is in sync and healthy
REBUILD
Rebuild in progress
FAILED
The member is marked as faulty by MD, or RAID0 has no redundancy
OFFLINE
The entire array is inactive, or the member has disappeared from the MD sysfs slaves
The remove function supports both VROC and Linux MD resources. When a drive group is removed, the associated physical drives and virtual drives are also removed from Graid management. The remove function does not modify or delete any VROC or Linux MD array. Linux MD can be removed from Graid management at any time. For the VROC arrays, the remove function verifies the existence of the superblock before remove from Graid management.
To remove a drive group, run the following command:
$ sudo graidctl remove drive_group [DG_ID][flag]
Example output:
$ sudo graidctl remove drive_group 0-t md✔Remove drive group successfully.✔Remove drive group MD DG0 successfully.
Command options:
Flag
Description
-h, --help
help for drive_group
-t, --type string
Specify product type of Drive Group, VROC or MD (default "VROC")
To delete a drive group, run the following command:
Note
You cannot delete a drive group that contains a virtual drive.
$ sudo graidctl delete drive_group [DG_ID][flag]
Alternatively:
$ sudo graidctl del dg [DG_ID][flag]
Command options:
Flag
Description
--confirm-to-delete
Confirm to delete DG forcibly
-t, --type string
Specify product type of Physical Drive, SR, VROC or MD
Example output: In this example, drive group 1 was not deleted because it contains a virtual drive. Drive groups 0 and 2 were deleted successfully.
$ sudo graidctl del dg 0Do you really want to delete DG0? [y/N]: y✔Delete drive group successfully.✔Delete drive group SR DG0 successfully.$ sudo graidctl del dg 1Do you really want to delete DG1? [y/N]: y✖Delete drive group failed: Failed to delete some DGs.✖Delete drive group VROC DG1 failed: rpc error code=FailedPrecondition des = DG1 still has 1VD(s)
Only SR drive groups configured as RAID 5 or RAID 6 support expansion, with a maximum of 32 PDs per DG.
The DG must be in the OPTIMAL state.
Expansion is not supported for SPDK DGs or DGs created with driver versions earlier than 1.3.x.
DGs containing mixed PD types, such as SATA and NVMe, cannot be expanded.
Physical drives
New PDs must be in the UNCONFIGURED_GOOD state. Assigned drives, OS drives, and hot spare PDs cannot be added.
New PDs must have attributes that match the DG and be the same type as its existing PDs. For example, SCSI PDs cannot be added to an NVMe DG, and NVMe-oF PDs cannot be added to a local NVMe DG.
Each new PD must have at least the same capacity as the existing PDs in the DG.
During expansion
Drive group expansion cannot be canceled after it starts.
Expansion runs only while the DG is OPTIMAL.
Expansion cannot start during copyback. Additional PDs cannot be added while expansion is in progress.
Only one DG expansion can run per controller/CX at a time.
Rebuild journal space is required, and the rebuild journal is forced on during expansion.
Manual consistency checks (CC) are unavailable during expansion; scheduled consistency checks are aborted.
If multiple drive groups require simultaneous recovery, the drive groups recover individually. If multiple physical drives in the same drive group require rebuilding, the physical drives are rebuilt simultaneously.
If a damaged drive group is initialized or a recovering drive group encounters an abnormal system crash, the data integrity of the drive group is affected. In this event, the drive group is forced offline to prevent data from being written to the drive group. To read the data for the drive group, force the drive group to go online using Rescue mode.
Note
A drive group in Rescue mode is read-only. Rescue mode cannot be disabled.
To enter rescue mode, run the following command:
$ sudo graidctl edit drive_group [DG_ID] rescue_mode on
See Setting Up the Auto-mount File Systems on Linux Using the SupremeRAID™ Driver. It is critically important to follow these instructions to guarantee that the RAID group mounts automatically during system boot and to avoid any improper or unclear shutdown processes that could cause the RAID group to enter resync mode.
To list virtual drives, run the following command:
$ sudo graidctl list virtual_drive [flag]
Alternatively:
$ sudo graidctl ls vd [flag]
Command options:
Flag
Description
-h, --help
Help for the list virtual_drive command
-d, --dg-id
[string] List VDs of a certain DG ID
-v, --vd-id
[string] List certain VD IDs
Example output:
$ sudo graidctl ls vd✔List virtual drive successfully.│──────────│───────│───────│─────────│─────────────│─────────│───────────────││ TYPE (4) │ VD ID │ DG ID │ SIZE │ DEVICE PATH │ STATE │ EXPORTED ││──────────│───────│───────│─────────│─────────────│─────────│───────────────││ SR │ 0 │ 0 │ 1.5 TiB │ /dev/gdg0n1 │ OPTIMAL │ No ││ VROC │ 0 │ 0 │ 3.5 TiB │ /dev/md123 │ OPTIMAL │ Not Supported ││ VROC │ 0 │ 1 │ 600 GiB │ /dev/md125 │ OPTIMAL │ Not Supported ││ VROC │ 0 │ 2 │ 0 B │ │ OFFLINE │ Not Supported ││──────────│───────│───────│─────────│─────────────│─────────│───────────────│
$ sudo graidctl ls vd✔List virtual drive successfully.│──────│───────│───────│─────────│─────────────│──────────│───────────────││ TYPE │ VD ID │ DG ID │ SIZE │ DEVICE PATH │ STATE │ EXPORTED ││──────│───────│───────│─────────│─────────────│──────────│───────────────││ MD │ 0 │ 0 │ 2.0 GiB │ /dev/md127 │ DEGRADED │ Not Supported ││──────│───────│───────│─────────│─────────────│──────────│───────────────│
Output fields:
Flag
Description
DG ID
Drive group ID
VD ID
Virtual drive ID
SIZE
Usable size of the virtual drive
DEVICE PATH
Device path of the virtual drive
NQN
NQN of the virtual drive
STATE
Virtual drive state - identical to the drive group state (see the following table)
EXPORTED
Shows whether the virtual drive was exported using NVMe-oF or iSCSI
Note
Do not perform I/O before the virtual drive is initialized and the device path (for example, /dev/gdgXnY) is created.
Virtual drive state:
State
Description
OFFLINE
Drive group is not working normally. This condition is usually caused when the number of damaged physical drives exceeds the limit.
OPTIMAL
Drive group is in the optimal state.
DEGRADED
Drive group is available and ready for use, but the number of missing or failed physical drives has reached the limit.
PARTIALLY_DEGRADED
Drive group is available and ready for use, but some physical drives are missing or failed.
RECOVERY
Drive group is recovering.
FAILED
Drive group is not working normally.
INIT
Drive group is initializing.
RESYNC
Drive group is resynchronizing and remains available and ready for use. This condition usually occurs when the system encounters an abnormal crash. Do not replace the physical drive in this state until the resynchronization process completes.
RESCUE
Drive group is in rescue mode and can only be read.
Stripe-cache state:
State
Description
OFFLINE
Stripe cache drive group is OFFLINE.
CLEAN
Stripe cache write-back has finished.
PURGE
Stripe cache is writing data into the virtual drive.
Increase the size of an existing virtual drive (VD) to use capacity made available by drive group expansion. Wait until DG expansion completes before resizing the VD.
You must disable the SupremeRAID™ controller before you can delete it. Disabling the controller prevents further access to it and its associated drives, allowing you to delete the controller safely without affecting the system's operation.
To delete a controller, run the following command:
Follow these guidelines when replacing a controller license key:
Disable the Controller: Before replacing the license key for a controller in SupremeRAID™, disable the controller to ensure it is not in use. This prevents access to the controller and its associated drives, allowing the license key to be replaced safely without affecting system operation.
Ensure Compatibility: You cannot replace a license key with one that has a different architecture or supported features. Use the same license key or a compatible replacement to avoid replacement issues.
Delete Inactive or Invalid Licenses: If you are replacing a card in the system, delete any inactive or invalid licenses associated with the old card. Failing to do so may prevent other cards from becoming active, which is especially important in multi-controller systems.
To replace a controller’s license key, run the following command:
After installing the SupremeRAID™ driver and the graidctl utility, SupremeRAID™ can import and control an MD bootable NVMe RAID. This feature makes it easy to swap drives if a bootable drive malfunctions.
Note
You must disable the SupremeRAID™ controller before you can delete it. Disabling the controller prevents further access to it and its associated drives, allowing you to delete the controller safely without affecting the system's operation. For instructions on setting up the MD bootable NVMe RAID, see Configuring Boot-Drive Devices.
The Create function supports only two NVMe drives. At least one of the selected drives must contain an EFI System Partition (ESP). The function creates a Linux MD RAID 1 array using the two selected drives.
$ sudo graidctl create md /dev/nvme0n1 /dev/nvme1n1
Detect none-RAID primary/backup EFI boot partition: /dev/nvme0n1p1, /dev/nvme1n1p1
Going to create RAID1 protection on them.
Data will sync from /dev/nvme0n1p1 to /dev/nvme1n1p1 (y/N)?: y
✔Create md drive successfully.
The Import function supports only Linux Multiple Device (MD) RAID 1 arrays consisting of two NVMe drives, with at least one drive containing an EFI System Partition (ESP). Currently, up to four MD arrays on the two NVMe drives are supported.
To import an MD bootable NVMe RAID, run the following command:
To scan all NVMe and SCSI drives and restore the latest SupremeRAID™ configuration, run the following command:
$ sudo graidctl restore config [flags]
Alternatively:
$ sudo graidctl re conf [flags]
Command options:
Flag
Description
-h, --help
Help for the restore config command
-a, --auto
Selects the last configuration automatically
Example output:
Values masked in the original captures are shown as [redacted].
$ sudo ./graidctl/cmd/graidctl/graidctl re config
/dev/nvme0n1: Config integrity check Passed!
Skip /dev/nvme1n1(nqn.[redacted]): no config found
Skip /dev/nvme2n1(nqn.[redacted]): no config found
Skip /dev/nvme3n1(nqn.[redacted]): no config found
/dev/nvme4n1: Config integrity check Passed!
Skip /dev/nvme5n1(nqn.[redacted]): no config found
Skip /dev/nvme6n1(nqn.[redacted]): no config found
/dev/nvme7n1: Config integrity check Passed!
Skip /dev/sda(t10.ATA QEMU HARDDISK ROOTDISK): no config found
Skip /dev/sdb(t10.ATA QEMU HARDDISK SN_0001): no config found
Found the following configs:
[ INDEX ]: The latest config recommended for restoration
[ 0]: Device /dev/nvme0n1(nqn.[redacted]), UUID [redacted], Epoch 8, Time 2025-06-23 15:01:37 +0800 CST
1 : Device /dev/nvme4n1(nqn.[redacted]), UUID [redacted], Epoch 6, Time 2025-06-23 14:59:16 +0800 CST
[ 2]: Device /dev/nvme7n1(nqn.[redacted]), UUID [redacted], Epoch 8, Time 2025-06-23 15:01:37 +0800 CST
Please select one config to restore (0-2): 1
Timestamp: 2025-06-23 14:59:16 +0800 CST
Epoch: 6
Config UUID: [redacted]
Physical Drive List:
+-------+-------+----------------+-------+----------+
| PD ID | DG ID | NQN/WWID | MODEL | CAPACITY |
+-------+-------+----------------+-------+----------+
| 0 | N/A | nqn.[redacted] | N/A | N/A |
| 1 | N/A | nqn.[redacted] | N/A | N/A |
| 2 | N/A | nqn.[redacted] | N/A | N/A |
+-------+-------+----------------+-------+----------+
Drive Group List:
No DG found
Warning: This is an unsafe operation!
Restore LEGACY config from PD to /etc/graid.conf may cause data inconsistency or data loss.
Proceed only if you fully understand the risks and have verified your backup.
To confirm, type (Case sensitive): 'Confirm Unsafe Operation'
Restore Config Auto Output
To restore a configuration from a file, run the following command:
$ sudo graidctl restore config --file[FilePath]
Example output:
$ sudo ./graidctl/cmd/graidctl/graidctl re config --file ~/graid.conf
/home/hann/graid.conf: Config integrity check Passed!
Timestamp: 2025-06[redacted]
Epoch: 41
Config UUID: 863fb[redacted]
Physical Drive List:
+-----------+-------+----------------+----------------+----------+
| PD ID (8) | DG ID | NQN/WWID | MODEL | CAPACITY |
+-----------+-------+----------------+----------------+----------+
| 0 | 0 | nqn.[redacted] | QEMU NVMe Ctrl | 7.9 GiB |
| 1 | 1 | nqn.[redacted] | QEMU NVMe Ctrl | 7.9 GiB |
| 2 | 0 | nqn.[redacted] | QEMU NVMe Ctrl | 7.9 GiB |
| 3 | 1 | nqn.[redacted] | QEMU NVMe Ctrl | 7.9 GiB |
| 4 | 0 | nqn.[redacted] | QEMU NVMe Ctrl | 7.9 GiB |
| 5 | 1 | nqn.[redacted] | QEMU NVMe Ctrl | 7.9 GiB |
| 6 | 0 | nqn.[redacted] | QEMU NVMe Ctrl | 7.9 GiB |
| 7 | 1 | nqn.[redacted] | QEMU NVMe Ctrl | 7.9 GiB |
+-----------+-------+----------------+----------------+----------+
Drive Group List:
+-------+-------+--------+----------+
| DG ID | MODE | VD NUM | CAPACITY |
+-------+-------+--------+----------+
| 0 | RAID5 | 3 | 22 GiB |
| 1 | RAID6 | 3 | 15 GiB |
+-------+-------+--------+----------+
Warning: This is an unsafe operation!
Restore config from file to /etc/graid.conf may cause data inconsistency or data loss.
Proceed only if you fully understand the risks and have verified your backup.
To confirm, type (Case sensitive): 'Confirm Unsafe Operation'
Confirmation: Confirm Unsafe Operation
✔Restore config graid.conf successfully.
Restore Config File Output
Note
The restore command does not support restoring configuration files created by a newer driver version. Therefore, it cannot be used to downgrade the driver to an earlier version.
To check detailed information from record, run the following command:
$ sudo graidctl list event [flags]
Alternatively:
$ sudo graidctl ls event [flags]
Command options:
Flag
Description
-h, --help
Help for the list event command
-n, --max_entries
[int32] Limit the number of events returned
-o, --output
[string] Output to a file
-s, --severity
[string] Filter events by severity
Example output:
[graid@graid-demo ~]$ sudo graidctl list event -n 10 -s INFO -c DG
✔List event successfully.
[2022-06-22 22:06:29 +0800 CST][INFO][DG][0] State transitted from UNKNOWN to OFFLINE.
[2022-06-22 22:20:07 +0800 CST][INFO][DG][0] Drive group deleted.
[2022-06-22 22:21:13 +0800 CST][INFO][DG][0] State transitted from UNKNOWN to OPTIMAL.
[2022-06-22 22:21:13 +0800 CST][INFO][DG][0] Drive group created.
[2022-06-22 22:28:02 +0800 CST][INFO][DG][0] Drive group deleted.
[2022-06-22 22:28:20 +0800 CST][INFO][DG][0] State transitted from UNKNOWN to OPTIMAL.
[2022-06-22 22:28:20 +0800 CST][INFO][DG][0] Drive group created.
[2022-06-22 22:30:15 +0800 CST][INFO][DG][0] CC has started.
[2022-06-22 23:26:57 +0800 CST][INFO][DG][0] CC has completed.
[2022-06-22 23:26:57 +0800 CST][INFO][DG][0] CC has started.
To connect to a remote NVMe-oF target, run the following command:
$ sudo graidctl connect remote_target [transport type][addr][address family][port service id]
Alternatively:
$ sudo graidctl conn rt [transport type][addr][address family][port service id]
Required parameters:
Option
Description
transport type
Network fabric used for an NVMe-over-Fabrics network. Current string values include: • RDMA = network fabric is an RDMA network (RoCE, iWARP, InfiniBand, basic RDMA, etc.) • TCP = network fabric is a TCP/IP network.
ip address
Network address of the controller
address family
Network address protocol. Current string values include ipv4/ipv6.
The integrated SPDK target exports SupremeRAID™ virtual drives to remote clients over NVMe-oF TCP or RDMA. It runs in the management daemon and uses the GPU RAID engine through a user-space I/O path. You do not need a separate SPDK instance.
Prepare hugepages and CPU cores first. Then enable the SPDK service, change the drive group to SPDK mode, and create export targets. All VDs in the selected DG move to SPDK access.
To enable Integrated SPDK target follow these guidelines:
SPDK mode applies to the entire drive group (DG). All virtual drives within that group will no longer have the kernel /dev/gdgXnY devices.
It is recommended to allocate a total of 8 GB of hugepages for stability.
The default block size of a virtual drive (VD) in SPDK mode is 4K. These VDs can optionally be configured in 512-byte LBA emulation (512e) mode.
For parameters related to Integrated SPDK target, see the configuration file /etc/graid/graid_spdk.conf.
The reactor_mask option in the configuration file specifies a bitmask of the CPU cores on which SPDK is allowed to execute work items. If it is not set, the SPDK reactors will not be launched, and the integrated SPDK features will not be available. You must configure reactor_mask before starting the Graid service to enable the SPDK export target. Once the Graid service is running, the reactor_mask setting cannot be changed.
SPDK requires at least 4 GiB of HugeTLB pages. Use 8 GiB where possible and check /etc/graid/graid_spdk.conf for your configuration. Each hugepage must be 1 GiB (hugepagesz=1G). Reserve pages at boot to reduce allocation failures caused by memory fragmentation.
Boot-Time Allocation (Persistent)
To reserve 8 GiB of HugeTLB pages during system boot, append the following parameters to the kernel command line: hugepagesz=1G hugepages=8
Allocations made through sysfs do not persist after a reboot. Configure boot-time allocation or a startup mechanism that applies the settings before the SupremeRAID™ service starts. The service cannot initialize without the required pages.
NUMA-Aware Allocation
On non-uniform memory access (NUMA) architectures, SPDK performance depends on proper memory locality. In order to achieve optimal performance, each NUMA node specified in the reactor_mask requires a minimum of 1 GiB of HugeTLB pages. Furthermore, the default performance profile defined in /etc/graid/graid_spdk.conf requires a minimum allocation of 3 GiB of HugeTLB pages on NUMA node 0.
To provision HugeTLB pages on specific NUMA nodes dynamically:
Edit the configuration file: /etc/graid/graid_spdk.conf and bind SPDK reactors to specific CPU cores to enable the integrated SPDK service. For example, to bind CPU cores 0 to 3 to the integrated SPDK service, set the reactor_mask:
See the previous sections for instructions on creating physical drive (PD), drive group (DG) and virtual drive (VD). If a DG was created with zero-init, wait until initialization is complete before switching to SPDK mode.
Change the drive group to SPDK mode. All VDs in that DG become SPDK block devices, and their /dev/gdg* devices are no longer available. Kernel and SPDK access cannot coexist in one DG.
Only SPDK-enabled virtual drives can be exported to SPDK export targets. Once an SPDK virtual drive has been exported with 512-byte LBA emulation, the same virtual drive cannot be exported to another SPDK export target with default 4K LBA size.
To list all SPDK NVMe-oF export targets, see Listing Created NVMe-oF Export Targets. As shown in the output, the target type will display SPDK instead of Kernel.
+----+------+-----------+-----------+-------------+----------------+------------+------------+
| ID | TYPE | TRANSPORT | INTERFACE | ADDRESS | ADDRESS FAMILY | SERVICE ID | SUBSYSTEMS |
+----+------+-----------+-----------+-------------+----------------+------------+------------+
| 0 | SPDK | tcp | enp0s1 | 172.16.32.6 | ipv4 | 4420 | DG0/VD0 |
| 1 | SPDK | tcp | enp0s1 | 172.16.32.6 | ipv4 | 4421 | DG1/VD0 |
+----+------+-----------+-----------+-------------+----------------+------------+------------+
The consistency check operation verifies that the data is correct in DGs that use RAID levels 1, 5, 6, and 10. In a system with parity, for example, checking consistency calculates the data on one drive and compares the results to the contents of the parity drive.
Note
You cannot perform a consistency check on RAID 0 because it does not provide data redundancy. Additionally, a consistency check can only run when the DG is in OPTIMAL or PARTIALLY_DEGRADED state.
The consistency check function records all events to the event database, and graidctl provides commands to retrieve the events. The maximum number of event entries is 1,000. The system deletes event entries periodically. You can also delete entries manually.
These examples show the installers for the named distribution versions. Other versions can use different steps or labels. Check your distribution documentation before you change boot storage. You cannot configure these boot-drive devices across multiple operating systems.
Storage partitions must be created and configured during the Ubuntu Server 20.04 installation. The partitions are required for mounting /boot, swap, and root/. Each partition functions as a software RAID.
Step 1 From the Guided storage configuration page, select Custom storage layout.
Ubuntu Custom Storage Layout
Step 2 From the Storage configuration page, select the first disk and choose Use As Boot Device.
Ubuntu Use First Disk As Boot Device
Step 3 From the Storage Configuration page, select the second disk and Use As Another Device.
Ubuntu Used Devices List
Step 4 Devices used for the MD bootable RAID will be listed as USED DEVICES in the interface.
Ubuntu Add GPT Partition Menu
Step 5 From the Disk menu, select free space and choose Add GPT Partition. Leave both disks unformatted.
A. Select first drive and select Add GPT Partition.
Ubuntu First Drive Unformatted Partition
B. Leave the drive unformatted.
Ubuntu Select Second Boot Drive
C. Select another drive for OS bootable RAID.
Ubuntu Second Drive Unformatted Partition
D. Leave the drive also unformatted.
Ubuntu Create Software RAID MD Menu
Note
You must use [Leave unformatted]. DO NOT mount the partition. Setting RAID1 and mounting partitions on multiple drives (MD) occurs later in this procedure.
Creating a Software RAID for Multiple Devices (MD)
To create the software RAID on multiple devices, from the Storage configuration page, select Create software RAID (md).
Step 1 Select Create Software RAID (md) for the previously configured disks.
Ubuntu Select Partitions For Software RAID
Step 2 Select the configured partitions on both disks, then create the Software RAID (md).
Ubuntu Software RAID CreatedUbuntu MD Free Space Add GPT Partition
Configuring the Boot Partition for MD
The following procedure describes how to configure the /boot, swap, and root partitions on both disks to set MD as the mounting point:
Step 1 Select the free space option in the md, then Choose Add GPT Partition.
Ubuntu MD EFI Partition Size
Step 2 Set the size of the EFI System Partition (ESP). Allocate sufficient capacity for each partition based on anticipated usage.
When installing SLES 15 SP2 or SP3, you must manually create RAID1 and configure the partitions. To manually create RAID1 and configure the partitions:
Step 1 From the SUSE Suggested Partitioning page, select Expert Partitioner > Next.
SLES Expert Partitioner
Step 2 From the SUSE Add menu, select Add > RAID.
SLES Add RAID Menu
Step 3 From the SUSE Add RAID page, select RAID 1 (Mirroring) for the RAID Type.
SLES Add RAID1 Mirroring
Step 4 From the Selected Devices list, select two NVMe disks and click Add.
SLES Select NVMe Disks For RAID
Step 5 Click Next to continue with the installation.
Plan downtime for the source and target hosts. Record the member drives and resource IDs. Preserve a configuration backup and a verified data backup. Stop applications and unmount affected filesystems on the source host before moving hardware. Follow one restore method below.
The following procedure describes how to migrate the RAID configuration manually between hosts.
To restore a RAID configuration from a backup configuration file:
Step 1 Periodically back up the configuration file /etc/graid.conf from the original host. Use cp or scp to move the configuration file to another system.
Step 2 Set up the target host and ensure that the SupremeRAID™ service is stopped.
Note
If the target host already contains an installed and running SupremeRAID™ card, stop the service and copy the graid.conf file from the original system. On the original system, stop any running applications or unmount the mountpoint before starting the SupremeRAID™ service.
Step 3 Move all the SSDs from the original host to the new host.
Step 4 Install the SupremeRAID™ driver on the new server. Stop the SupremeRAID™ service before copying the configuration backup file to the new host using the same path (/etc/graid.conf). If the management console is enabled, stop its service as well.
Use the metadata stored on the SSDs to restore a RAID configuration when a configuration backup is not available. Move all member SSDs to the target host before you run the restore command.
To restore a RAID configuration from an SSD’s metadata:
Step 1 Set up the target host and make sure that the SupremeRAID™ service is stopped.
Note
If the target host already contains an installed and running SupremeRAID™ card, stop the SupremeRAID™ service before restoring the configuration. On the original system, stop any running applications or unmount the mountpoint before starting the SupremeRAID™ service.
Step 2 Move all the SSDs from the original host to the new host.
Step 3 Install the SupremeRAID™ driver on the new server and stop the SupremeRAID™ service before restoring the configuration file. If the management console is enabled, stop its service as well.
Step 4 Run the restore command and restore the configuration file from SSD's metadata.
$ sudo graidctl restore config
$ sudo ./graidctl/cmd/graidctl/graidctl re config
/dev/nvme0n1: Config integrity check Passed!
Skip /dev/nvme1n1(nqn.[redacted]): no config found
Skip /dev/nvme2n1(nqn.[redacted]): no config found
Skip /dev/nvme3n1(nqn.[redacted]): no config found
/dev/nvme4n1: Config integrity check Passed!
Skip /dev/nvme5n1(nqn.[redacted]): no config found
Skip /dev/nvme6n1(nqn.[redacted]): no config found
/dev/nvme7n1: Config integrity check Passed!
Skip /dev/sda(t10.ATA QEMU HARDDISK ROOTDISK): no config found
Skip /dev/sdb(t10.ATA QEMU HARDDISK SN_0001): no config found
Found the following configs:
[ INDEX ]: The latest config recommended for restoration
[ 0]: Device /dev/nvme0n1(nqn.[redacted]), UUID [redacted], Epoch 8, Time 2025-06-23 15:01:37 +0800 CST
1 : Device /dev/nvme4n1(nqn.[redacted]), UUID [redacted], Epoch 6, Time 2025-06-23 14:59:16 +0800 CST
[ 2]: Device /dev/nvme7n1(nqn.[redacted]), UUID [redacted], Epoch 8, Time 2025-06-23 15:01:37 +0800 CST
Please select one config to restore (0-2): 1
Timestamp: 2025-06-23 14:59:16 +0800 CST
Epoch: 6
Config UUID: [redacted]
Physical Drive List:
+-------+-------+----------------+-------+----------+
| PD ID | DG ID | NQN/WWID | MODEL | CAPACITY |
+-------+-------+----------------+-------+----------+
| 0 | N/A | nqn.[redacted] | N/A | N/A |
| 1 | N/A | nqn.[redacted] | N/A | N/A |
| 2 | N/A | nqn.[redacted] | N/A | N/A |
+-------+-------+----------------+-------+----------+
Drive Group List:
No DG found
Warning: This is an unsafe operation!
Restore LEGACY config from PD to /etc/graid.conf may cause data inconsistency or data loss.
Proceed only if you fully understand the risks and have verified your backup.
To confirm, type (Case sensitive): 'Confirm Unsafe Operation'
Restore Configuration From Ssd Metadata Output
Step 5 If the original card also moved to the new host, start the SupremeRAID™ service directly.
$ sudo systemctl start graid
Step 6 (Optional) If the card changed, you must apply the new license.
$ sudo graidctl apply license [LICENSE_KEY]
Verify the migration
On the target host, check the license and list the controllers, PDs, DGs, and VDs. Compare the results with the source inventory. Confirm that the expected volumes and filesystems are available before you resume applications. If a member drive or volume is missing, stop and investigate before writing data.
If the SupremeRAID™ service does not start properly after upgrading the kernel, reinstall the SupremeRAID™ pre-installer and the installer to ensure that they are configured properly for the new kernel environment.
To reinstall the SupremeRAID™ pre-installer and installer on new kernel, follow these steps:
Step 1 Download the pre-installer and installer for your installed driver release. For 2.0.1, use the 2.0.1 release notes. Confirm that the new kernel is supported. Make both files executable.
$ sudochmod +x [Filename]
Step 2 Open a terminal window and log in to the system as a user with root privileges.
Step 3 Use the cd command to navigate to the directory where the downloaded installer files are located.
Step 4 Run the graid-sr-pre-installer and follow the on-screen instructions to complete the pre-installation process.
Step 5 Run the graid-sr-installer and follow the on-screen instructions to complete the installation process.
Step 6 After installing the SupremeRAID™ pre-installer and installer, restart the SupremeRAID™ service and verify it is running correctly in the new kernel environment.
Self-Monitoring, Analysis and Reporting Technology (SMART) data is a set of metrics and parameters that SSDs collect and monitor to assess their health and performance. Although the specific information included in the SMART data varies by manufacturer and drive model, it typically reports on the temperature, available spare capacity, power-on hours, error rates, and other details that are used to monitor the health of the SSD and predict its future performance.
By monitoring the SMART data for an SSD, you can identify a potential issue or degradation of the drive before it becomes a serious problem.
To check the SMART information for the gpd device using the NVMe smart-log or smartctl command, follow these steps:
Step 1 Open a terminal window and log in to the system with administrative privileges.
Step 2 Use the list physical drives command to identify the device name for the gpd device, such as /dev/gpdx.
$ sudo graidctl list physical_drive
Step 3 Use the nvme command to display the SMART data for the gpd device:
$ sudo nvme smart-log /dev/gpd[#]
Alternatively, you can use the smartctl command to display the SMART data for the gpd device:
$ sudo smartctl -d nvme -a /dev/gpd[#]
A detailed report of the SMART data for the gpd device, including the temperature, available spare capacity, and other details, appears. Use this information to monitor the health and performance of the device and to diagnose any potential issues.
Note
The specific steps and commands used to display SMART data may vary, depending on your system and the version of the nvme or smartctl command in use. Be sure to use the correct device name for the gpd device in the command.
The following example shows the output using nvme smart-log.
The sysstat package contains the tools most commonly used to monitor I/O statistics in Linux systems. The sysstat package includes the iostat tool, which monitors system I/O device loading by observing the time the devices are active relative to their average transfer rates. The iostat command generates reports that allow you to fine-tune the system configuration to better balance the I/O load between physical disks.
For example, to monitor specific devices and display statistics in megabytes per second (MB/s), run the following command:
For sysstat versions v12.3.3 and later, the iostat tool includes an alternative directory feature that allows you to specify the directory from which to read device statistics.
Add a +f parameter to the tool and use the /sys/devices/virtual/graid/graid sysfs device path to read device statistics from both the standard kernel files and the files in the alternative directory.
The following excerpt from the iostat manual describes the alternative directory option.
-f directory
+f directory
Specify an alternative directory for iostat to read devices statistics. Option -f tells iostat to use only the files located
in the alternative directory, whereas option +f tells it to use both the standard kernel files and the files located in the
alternative directory to read device statistics.
directory is a directory containing files with statistics for devices managed in userspace. It may contain:
- a "diskstats" file whose format is compliant with that located in "/proc",
- statistics for individual devices contained in files whose format is compliant with that of files located in "/sys".
In particular, the following files located in directory may be used by iostat:
directory/block/device/stat
directory/block/device/partition/stat
partition files must have an entry in directory/dev/block/ directory, e.g.:
directory/dev/block/major:minor --> ../../block/device/partition
iostat Alternative Directory Manual
To check the iostat version, run the following command:
For operating systems with sysstat versions prior to v12.3.3 (for example, CentOS), Graid Technology provides an alternate tool called giostat to display device statistics.
In the following example, the operating system version of iostat is prior to v12.3.3.
The giostat and iostat tools are very similar and their usage is the same. Set the parameter preferences using giostat. The following example shows the output.
Step 2 For a new, empty VD, create a filesystem and mount point. Formatting erases existing filesystem data. If the VD already contains a filesystem, skip mkfs and use its existing filesystem type.
Step 3 Identify the persistent device link and filesystem type. Replace gdgXnY with the VD device path. Select the link that resolves to this VD.
$ ls-l /dev/disk/by-id/$ lsblk -f /dev/gdgXnY
Step 4 Edit the /etc/fstab file:
A. Edit the /etc/fstab file.
$ sudovim /etc/fstab
B. Append one line of code to the end of the file using the following format.
RHEL-family example. Replace [VD_DEVICE_ID] with the complete link name from /dev/disk/by-id/. Replace the mount point and filesystem type with your values. These are file entries, not shell commands.
C. Review the example below. The highlighted VD entry illustrates the Debian-family dependency option; the other entries belong to the captured example host. Do not copy its complete file.
To remove a persistent mount, stop applications that use it and unmount the filesystem. Remove or comment out only its entry in /etc/fstab. Do not delete a VD while its filesystem is mounted.
Resolve reported errors before rebooting. During a planned restart, confirm that the VD is available and that access to its mount point works before you resume applications.
You can create virtual machines with SupremeRAID™ support to maximize performance.
The following procedure describes how to set a single VM with SupremeRAID™. This setup is for use only within a single virtual machine and cannot be shared from the volume back to ESXi to a datastore for other virtual machines.
From the Navigator menu, select Host > Enter maintenance mode.
ESXi Enter Maintenance Mode
Managing PCI Device Passthrough
Step 1 From the Navigator menu, select Manage > Hardware > PCI Devices. The Passthrough Configuration page appears, listing all available passthrough devices.
Step 2 Select the NVIDIA T1000 (Quadro T1000 Mobile) and its Audio device.
Step 3 Click Toggle passthrough.
Step 4 Confirm that the Passthrough status is Active.
ESXi Pci Passthrough Active
Note
If you move the SupremeRAID™ card to a different hardware slot or plan to do so, you MUST cancel its passthrough before shutting down the ESXi server. After the hardware change, you MUST set up the passthrough again; otherwise, the virtual machine will not recognize the PCIe device properly.
Self-Encrypting Drives (SEDs) provide hardware-based full-disk encryption, ensuring data security by automatically encrypting all data written to the drive and decrypting data read from it. SupremeRAID™ supports managing SEDs, including setting encryption keys, taking ownership of drives, and securely erasing data. Before configuring an SED drive, follow these guidelines:
Before configuring an SED drive, follow these guidelines:
SED Key Configuration: The SED key must be configured using the graidctl tool before creating physical drives or during the creation process if the drive is not yet locked.
Supported Devices: Only NVMe devices are supported for SED configurations.
Locking Range: Only the global locking range is supported.
SupremeRAID™ allows you to import encryption keys (SED keys) to manage the SEDs. These keys are essential for unlocking drives during accessing data.
Importing a Single SED Key Using NQN/WWID
To import a single SED key for a specific drive identified by its NQN (NVMe Qualified Name) or WWID (World Wide Identifier), use the following command:
$ sudo graidctl edit config sed_key [NQN/WWID]
Importing a Batched SED Key Using NQN/WWID
To import multiple SED keys from a file, use the --input-file option:
You can create a physical drive with SED support directly from the command line using graidctl. The following options allow you to either import an existing SED key or take ownership of the SED during creation.
Importing an SED Key During PD Creation
To create a physical drive with an SED and import an existing key, use the --sed-import-key option:
To take ownership of a physical drive with SED support (if the drive is not yet locked), use the --sed-take-ownership option. The command will prompt you for confirmation, a new SED key, and credentials:
Note
This action will erase all user data on the drive.
When taking ownership, the SID and admin1 key will both be set to the same key (known as the SED key), and only this SED key will be stored in the system.
This enhancement improves how the SED unlock script handles scenarios where keys are retrieved from an external KMS (Key Management Server). It ensures that if the key is temporarily unavailable, the unlock process will not block service startup and can be retried later once the key becomes accessible.
SED Unlock Script Mechanism
Set sed_unlock_script to a script that retrieves the key and unlocks the SED when SupremeRAID™ creates a physical drive.
Config file: /etc/graid/graidserver.conf
Parameter: sed_unlock_script
SED Unlock Timeout Mechanism
Although the timeout mechanism is not required for all use cases, the systemd service for Graid still enforces a 180-second timeout. To provide flexibility, a configurable timeout parameter has been added, which can be disabled if needed.
Config file: /etc/graid/graidserver.conf
Parameter: sed_unlock_script_timeout_sec
Default: 60 seconds
Disable: Set to 0
Maximum: 120 seconds (any value above this will be capped automatically)
Note
This timeout is independent of the systemd Graid service timeout (180 seconds).
Physical Drive SED Unlock Failure
When the configured SED unlock script does not return a successful status, the following message will be displayed:
PD state: Changes to OFFLINE, and sed_state is set to Locked.
DG state on service start: If a PD is OFFLINE and sed_state=Locked, the DG transitions to OFFLINE.
Other DG transitions: Follow existing logic. For example, if a user hot-removes a drive, the DG enters the DEGRADED state. When the drive is reinserted and the unlock process fails, the DG remains DEGRADED instead of transitioning to OFFLINE. Even after a service restart, the failed unlock on that PD will not prevent the DG from coming up and entering the DEGRADED state.
Script return codes:
rc = 0: Unlock successful
rc = 2: PD marked as MISSING
rc = others: PD set to OFFLINE (Locked)
Retrying Unlock Manually
You can manually retry the SED unlock by bringing the PD back online:
The secure erase command uses the SED erase function to erase all data on the selected physical drives. All selected drives must support SED. Confirm the PD IDs before you run the command.
To securely erase physical drives, use the following command:
SupremeRAID™ offers a mail notification service in Linux that enables users to receive email notifications for monitoring service status. This includes actions like creating or deleting physical drives (PD), drive groups (DG), or virtual drives (VD) and so on.
Setup the Mail Notification Service
To set up mail notification service, run the following command:
$ sudo graid-mgr set notification [Command]
Related Commands:
Command
Description
on
Enable notification service
off
Disable notification service
smtp_host
Edit SMTP host
smtp_port
Edit SMTP port
smtp_user
Edit SMTP username
smtp_password
Edit SMTP password
sender_mail
Edit sender mail of notification service
Setup mail notification for admin user
To set up admin user email notification, run the following command:
$ sudo graid-mgr set admin [Command]
Related Commands:
Command
Description
email
Set email of user admin
notification
Configuration of notification
To view the configuration of the mail notification
To see the configuration of mail notification, run the following command:
$ sudo graid-mgr show notification$ sudo graid-mgr show admin
Copyback moves data from a source physical drive to a replacement drive without changing the overall drive group state. Start it when you need to replace an aging drive or move data before a hardware change. Check the source and destination requirements below before you start.
To initiate data copy from the source PD (SrcPD) to the destination PD (DstPD), follow these guidelines:
The drive group state for SrcPD must be OPTIMAL.
The DstPD state must be UNCONFIGURED_GOOD and not a hotspare in the drive group. If the DstPD is a hotspare, the -f flag must be used, and the DstPD must be a global hotspare or a hotspare under the SrcPD drive group.
DstPD and SrcPD must have identical capability (PD type, LBA size, DSM support, Write-uncor support).
A drive group can only execute one Copyback task at a time. If multiple drive groups are running Copyback, only one drive group will perform the Copyback task.
Use copyback physical drive as a hotspare of the drive group when physical drive failure
You can also log in to the SupremeRAID™ Management Console, then navigate to the RAID management / Drive Group section on the sidebar menu. Select the drive group which you want to perform the Copyback, and click the “Physical Drives” tab. Choose the physical drive, then click the “Actions” button to initiate the Copyback.
Record the exact error and the time it occurred before you change the host. Start with the matching symptom below. If no symptom matches, collect the service state and logs described in Service fails to start and contact Graid Technical Support.
Unlike SAS/SATA hard drives, many NVMe SSDs support the de-allocate dataset management command. Using this command, you can reset all data in the NVMe SSD immediately, eliminating the need to synchronize data between physical drives when creating a drive group.
For other SSDs, however, the performance is not as expected when reading unwritten sectors after issuing the de-allocate dataset management command. While this behavior also impacts the performance of the new drive group, it does not affect the applications because they do not read sectors that do not contain data.
Destructive test
A sequential write across an entire VD overwrites its contents. Use an empty, expendable test VD. Never run this preparation step against a production volume or data that you must retain.
For a controlled performance test, prepare the test VD with a sequential write using a large block size. Repeat the read test under the same conditions after the write completes.
Some NVMe SSD models might display a "failed to set APST feature (-19)" message in the kernel log when creating the physical drive.
When SupremeRAID™ creates the physical drive, the SSD is unbound from the operating system so the SupremeRAID™ can control the SSD. When the APST feature is enabled during the unbinding process, the NVMe driver tries and fails to set the APST state to SSD and the error message is issued. This message is expected and can be ignored. SupremeRAID™ is working normally.
You might notice that the HDD/SSD activity indicator blink pattern is different on SupremeRAID™ than on traditional RAID cards.
SupremeRAID™ does not require a buffering or caching mechanism to improve read/write performance as do traditional RAID cards. This feature causes SupremeRAID™ indicators to blink differently than traditional RAID cards.
To activate the SupremeRAID™ server with your license key, it’s essential to install the correct driver version that matches your specific SupremeRAID™ model. If the incorrect version is installed, the following error message appears when you try to activate the SupremeRAID™ server with a license key: Apply license failed: The arch of the controller and SupremeRAID™ software mismatched.
Run graidctl version to check the installed package. In the older package examples, the final numeric suffix identifies the model as follows. For 2.0.1, confirm your model with the release page selector.
Package suffix
SupremeRAID™ model
001
SR-1001
000
SR-1000
010
SR-1010
The example below shows a related license failure (No controller found for this license key). Its message differs from the architecture mismatch message above. If you confirm that the installed package does not support your card, use the following procedure to replace it.
[root@graid ~]# sudo graidctl version
✔Graidctl version successfully.
graidctl version: 1.6.0-rc1-243.g25b840a5.000
graid_server version: 1.6.0-rc1-243.g25b840a5.000
[root@localhost ~]# sudo graidctl apply license xxxxxxxx-xxxxxxxxxx
✘Apply license failed: No controller found for this license key
Historical example: license key has no matching controller
Step 1 Stop SupremeRAID™ service. If the management console is enabled, stop its service as well.
Step 3 Uninstall the package using the command appropriate for your operating system:
For CentOS, Rocky Linux, AlmaLinux, RHEL, openSUSE, and SLES:
$ sudorpm-e graid-sr
For Ubuntu:
$ sudo dpkg -r graid-sr
Step 4 Confirm that the SupremeRAID™ module is unloaded. The output should be empty.
$ sudo lsmod |grep graid
Step 5 Confirm that the SupremeRAID™ package is uninstalled using the command appropriate for your operating system, the output should be empty.
For CentOS, Rocky Linux, AlmaLinux, RHEL, openSUSE, and SLES:
$ sudorpm-qa|grep graid
For Ubuntu:
$ sudo dpkg -l|grep graid
Step 6 Install the correct SupremeRAID™ driver:
A. At the Welcome page, select Next and press Enter to view the end-user license agreement.
Correct Driver Installer Welcome Screen
B. In the end-user license agreement, use the spacebar to scroll through the content. When you complete your review, select Next and press Enter to proceed.
Correct Driver Installer License Review Screen
C. Type accept, press Tab, select Next, and press Enter to accept the license agreement.
The service can fail when the root partition is full. If the checks confirm this condition, free space under your host's retention policy. Preserve diagnostic logs until the cause is understood.
Verify recovery
After you correct the reported cause, start the service and check its state:
$ sudo systemctl start graid.service$ sudo systemctl is-active graid.service$ sudo graidctl list controller$ sudo graidctl list drive_group$ sudo graidctl list virtual_drive
Confirm that the service is active and that the expected storage resources are present. Investigate any degraded or missing resource before you resume applications.
If startup still fails, use the Graid log collection procedure. Provide the driver version, operating system, kernel version, failure time, and relevant error messages to Graid Technical Support. Do not include license keys or passwords in the problem description.
CE Directives Declaration: NVIDIA Corporation hereby declares that this device complies with all material requirements and other relevant provisions of the 2014/30/EU and 2011/65/EU. A copy of the Declaration of Conformity may be obtained directly from NVIDIA GmbH(Bavaria Towers - Blue Tower, Einsteinstrasse 172, D-81677 Munich, Germany)
NVIDIA products are designed to operate safely when installed and used according to the product instructions and general safety practices. The guidelines included in this document explain the potential risks associated with equipment operation and provide important safety practices designed to minimize these risks. By carefully following the information contained in this document, you can protect yourself from hazards and create a safer environment.
This product is designed and tested to meet IEC 60950-1 and IEC 62368-1 Safety Standards for Information Technology Equipment. This also covers the national implementations of IEC 60950-1/62368-1 based safety standards around the world e.g. UL 62368-1. These standards reduce the risk of injury from the following hazards:
Electric shock: Hazardous voltage levels contained in parts of the product
Fire: Overload, temperature, material flammability
Energy: Circuits with high energy levels (240-volt amperes) or potential as burn hazards.
Heat: Accessible parts of the product at high temperatures.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This product, as well as its related consumables and spares, complies with the reduction in hazardous substances provisions of the "India E-waste (Management and Handling) Rule 2016". It does not contain lead, mercury, hexavalent chromium, polybrominated biphenyls, or polybrominated diphenyl ethers in concentrations exceeding 0.1 weight %, and it does not contain cadmium in concentrations exceeding 0.01 weight %, except where allowed pursuant to the exemptions set in Schedule 2 of the Rule.
Retain and follow all product safety and operating instructions.
Always refer to the documentation supplied with your equipment. Observe all warnings on the product and in the operating instructions found on the product's User Guide.
This is a recycling symbol indicating that the product/battery cannot be disposed of in the trash and must be recycled according to the regulations and/or ordinances of the local community.Hot surface warning. Contact may cause burns. Allow to cool before servicing.
Physical Drive [PD_ID] state has transitioned from [STATE_OLD] to unconfigured bad.
Physical Drive
Critical
Physical Drive [PD_ID] state has transitioned from [OLD_STATE] to failed.
Physical Drive
Warning
Physical Drive [PD_ID] state has transitioned from [OLD_STATE] to offline.
Physical Drive
Critical
Physical Drive [PD_ID] state has transitioned from [OLD_STATE] to missing.
Physical Drive
Info
Physical Drive [PD_ID] state has transitioned from [OLD_STATE] to online.
Physical Drive
Info
Physical Drive [PD_ID] state has transitioned from [OLD_STATE] to rebuild.
Physical Drive
Info
Physical Drive [PD_ID] state has transitioned from [OLD_STATE] to unconfigured good.
Physical Drive
Info
Physical Drive [PD_ID] has been successfully created.
Physical Drive
Info
Physical Drive [PD_ID] has been deleted.
Physical Drive
Info
Physical Drive [PD_ID] has been hot-plugged.
Physical Drive
Warning
Physical Drive [PD_ID] has been hot-removed.
Physical Drive
Warning
The temperature of Physical Drive [PD_ID] is currently [CURRENT_TEMP] degrees, which exceeds the Warning threshold of [THRESHOLD_TEMP] degrees. Critical Warning error code: [ERROR_CODE].
Physical Drive
Critical
The temperature of Physical Drive [PD_ID] is currently [CURRENT_TEMP] degrees, which exceeds the Critical threshold of [THRESHOLD_TEMP] degrees. Critical Warning error code: [ERROR_CODE].
Physical Drive
Critical
The available spare capacity [AVAIL_SPARE] of Physical Drive [PD_ID] has fallen below the threshold [SPARE_THRESHOLD]. Critical Warning error code: [ERROR_CODE].
Physical Drive
Critical
The NVM subsystem reliability of Physical Drive [PD_ID] has been degraded due to significant media related errors or any internal error that degrades NVM subsystem reliability. Critical Warning error code: [ERROR_CODE].
Physical Drive
Critical
All of the media of Physical Drive [PD_ID] has been placed in read only mode. Critical Warning error code: [ERROR_CODE].
Physical Drive
Critical
The volatile memory backup device of Physical Drive [PD_ID] has failed. Critical Warning error code: [ERROR_CODE].
Physical Drive
Critical
The Persistent Memory Region of Physical Drive [PD_ID] has become read-only or unreliable. Critical Warning error code: [ERROR_CODE].
Physical Drive
Warning
Physical Drive [PD_ID] is currently experiencing a wearout level of WEAROUT, surpassing the Warning threshold of [THRESHOLD_WEAROUT].
Physical Drive
Critical
Physical Drive [PD_ID] is currently experiencing a wearout level of WEAROUT, surpassing the Critical threshold of [THRESHOLD_WEAROUT].
Drive Group
Fatal
Drive Group [DG_ID] state has transitioned from [OLD_STATE] to failed.
Drive Group
Critical
Drive Group [DG_ID] state has transitioned from [OLD_STATE] to offline.
Drive Group
Critical
Drive Group [DG_ID] state has transitioned from [OLD_STATE] to degraded.
Drive Group
Warning
Drive Group [DG_ID] state has transitioned from [OLD_STATE] to rescue.
Drive Group
Warning
Drive Group [DG_ID] state has transitioned from [OLD_STATE] to partially degraded.
Drive Group
Info
Drive Group [DG_ID] state has transitioned from [OLD_STATE] to optimal.
Drive Group
Info
Drive Group [DG_ID] state has transitioned from [OLD_STATE] to recovery.
Drive Group
Info
Drive Group [DG_ID] state has transitioned from [OLD_STATE] to init.
Drive Group
Info
Drive Group [DG_ID] state has transitioned from [OLD_STATE] to resync.
Drive Group
Info
Drive Group [DG_ID] has been successfully created.
Drive Group
Info
Drive Group [DG_ID] has been deleted.
Drive Group
Info
Consistency Check for Drive Group [DG_ID] has been manually aborted.
Drive Group
Info
Consistency Check for Drive Group [DG_ID] has been aborted due to the deletion of the Drive Group.
Drive Group
Info
Consistency Check for Drive Group [DG_ID] was aborted due to the Drive Group migrating from Controller [CX_OLD] to [CX_NEW].
Drive Group
Info
Consistency Check for Drive Group [DG_ID] has been aborted due to the Drive Group's state transitioning to [DG_STATE].
Drive Group
Info
Manual Consistency Check for Drive Group [DG_ID] has been completed.
Drive Group
Info
Scheduled Consistency Check for Drive Group [DG_ID] has completed.
Drive Group
Info
Manual Consistency Check for Drive Group [DG_ID] has started.
Drive Group
Info
Scheduled Consistency Check for Drive Group [DG_ID] has started.
Drive Group
Info
Inconsistency in Drive Group [DG_ID] has been fixed at: Drive Group block range: [DG_INTERS].
Drive Group
Critical
Inconsistency detected in Drive Group [DG_ID] at: Drive Group block range: [DG_INTERS].
Drive Group
Critical
Consistency Check for Drive Group [DG_ID] has been aborted due to the 'stop_on_error' policy.
Drive Group
Critical
Consistency Check for Drive Group [DG_ID] has been aborted due to numerous inconsistencies found and fixed.
Drive Group
Info
Journal Replay for Drive Group [DG_ID] has started.
Drive Group
Info
Journal Replay for Drive Group [DG_ID] has been completed. Entry replayed [REPLAYNR].
Drive Group
Critical
Journal Replay for Drive Group [DG_ID] has been waiting Physical Drive [PD_ID] to be active.
Drive Group
Critical
Journal Replay for Drive Group [DG_ID] has been aborted due to inconsistency detected on journal.
Virtual Drive
Info
Inconsistency for Virtual Drive [VD_ID] within Drive Group [DG_ID] has been fixed at: Virtual Drive block range: [VD_OFFSETS].
Virtual Drive
Critical
Inconsistency found in Virtual Drive [VD_ID] of Drive Group [DG_ID] at: Virtual Drive block range: [VD_OFFSETS].
Virtual Drive
Info
Virtual Drive [VD_ID] for Drive Group [DG_ID] has been created successfully.
Virtual Drive
Info
Virtual Drive [VD_ID] for Drive Group [DG_ID] has been deleted.
Virtual Drive
Info
Stripe cache for Virtual Drive [VD_ID] on Drive Group [DG_ID] has been deleted.
Virtual Drive
Info
Stripe cache for Virtual Drive [VD_ID] on Drive Group [DG_ID] has been created successfully.
Controller
Warning
The temperature of Controller [CX_ID] is currently [CURRENT_TEMP] degrees, which exceeds the GPU threshold of [THRESHOLD_TEMP] degrees.
Controller
Warning
The temperature of Controller [CX_ID] is currently [CURRENT_TEMP] degrees, which exceeds the GPU memory threshold of [THRESHOLD_TEMP] degrees.
Controller
Warning
The temperature of Controller [CX_ID] is currently [CURRENT_TEMP] degrees, it will cause controller slowdown.
Controller
Critical
The temperature of Controller [CX_ID] is currently [CURRENT_TEMP] degrees, it will cause controller shutdown.