SMART Errors Reported on Drives Configured in an Intel® Virtual RAID on CPU (Intel® VROC) RAID Volume on the Intel® Server Board S2600STBR
Article ID:0000894931/29/25
Environment
Intel® Server Board S2600STBR
Description
Suddenly encountered a SMART error on drives configured in Intel® VROC and still reoccurs even after suppressing the warnings from the Intel® VROC GUI.
Resolution
Try following the below recommendations:
- Reset the SMART errors on the drives and modify the cooling policy of the server.
- Download the latest version of the Intel® Server Board S2600ST Family BIOS and Firmware Update Package for UEFI. Reflash the BIOS and reupdate the FRU/SDR manually and separately by running UpdBIOS.nsh and once completed, run UpdS2600STBFRUSDR.nsh instead of running startup.nsh on a usual firmware update process.
If the above does not help, try the following recommendations:
- Shutdown and remove power cables from the PSU. This will reset the BMC.
- Wait for 10 seconds before reconnecting the power cable.
- Wait about 60 seconds for the blue LED on the front panel to go off, then only power on the system. This allows the BMC to finish booting.
- Wait for around 30 seconds after powering the system on to login to the BMC and get a new set of the debug log. See more information in How to Collect the Baseboard Management Controller (BMC) System Debug Log for Intel® Server Boards and Intel® Server Systems.
- Boot to Windows* and get the following information to contact Graid Technology Customer Support:
- Operating System Event Log.
- Windows* System Event Log.
- Windows* Application Event Log.
- Intel® VROC System Report. See more information in How to Get the System Report from the Intel® Virtual RAID on CPU (Intel® VROC) GUI Application in Windows*.